Power Failure Detection System; Error Information Table - Sanyo PLC-XP100L Service Manual

Hide thumbs Also See for PLC-XP100L:
Table of Contents

Advertisement

Chassis Description

Power failure detection system

detection of Power failure
Projector provides a protection circuit to prevent the secondary failure when the power failure, fans failure or tempera-
ture failure occurs on the projector. The power failure detection lines "S5V_AV_PF", "MAIN_-5V_PF", etc. are con-
nected to the main power supplies and fans. When the failure occurs, IC801<SH3, SYSTEM CONTROL> receives
an error information through the IC4801<I/O EXPANDER> and then outputs the signal "PFC_SW_CPU" from pin 186
to stop the power supply.
The power failure detection signals are sent to IC4801<I/O EXPANDER> and then sent to IC801<SH3, SYSTEM
CONTROL> .

Error information table

Ic
Pin
Signal Name
64
PJ_5V_PF
65
S-5V_AV_PF
66
S5V_AV_PF
67
MAIN_-5V_PF
68
M/A_PF
69
FAN_PF
70
SWF_1.V_PF
71
SWF_.5V_PF
7
VDEC_1.8V_PF
73
FPGA_1.5V_PF
IC4801
77
MAIN_6V_PF
78
MAIN_3.3V_PF
80
AD_3.3V_PF
8
VDEC_3_3V_PF
6
GAM_1.8V_PF
63
GAM_.5V_PF
86
GAM_3.3V_PF
88
GAM_13.5V_PF
56
LAMP_FAN_PF
47
9V_LNS_PF
46
15V_LNS_PF
166
FILTER_DET
IC801
9
FILTER_COUNT
33
PRESS_SENS
connection Lines
error Information
PJ_5V
PJNET,
-5V_AV
AV,
S5V
AV
MAIN_-5V
MAIN,
M/A_9V
M/A,
S16V, FAN LOCK
FAN,
SWF_1.V
SWFPGA1,
SWF_.5V
SWFPGA1,
VDEC_1.8V
VDEC,
FPGA_1.5V
FPGA,
MAIN_6V
MAIN,
MAIN_3.3V
MAIN,
AD_3.3V
ANALOG,
VDEC_3.3V
VDEC,
GAM_1.8V
GAMMA,
GAM_.5V
GAMMA,
GAM_3.3V
GAMMA,
13.5V
GAMMA,
S16V, FAN LOCK
LAMP FAN,
9V_LNS
LENS,
15V_LNS
LENS,
FILTER,
MOTOR, TIMOUT
PRESS,
-75-
Failure Area
S5V
5V line on Network Unit
S-5V
S-5V line on AV
S5V
S5V line on AV
S-5V
S-5V line on Main
9V
9V line on Main
S16V line on Fan Drive stage
16V
FN901, FN90, FN904
1.V
FPGA stage 1.V line
.5V
FPGA stage .5V line
1.8V
Video Decoder & A/D stage
1.V
6V
6V line on Main
3.3V
3.3V line on Main
3.3V
PC A/D stage 3.3V line
3.3V
Video Decoder & A/D stage
1.8V
Digital Gamma stage 1.8V
.5V
Digital Gamma stage .5V
3.3V
Digital Gamma stage 3.3V
13.5V
Panel Drive stage
S16V line on Fan Drive stage
16V
FN905, FN906, FN907, FN908
9V
Lens Motor Drive (Zoom/Focus)
15V
Lens Motor Drive (Lens Shift)
DET
Filter Cartridge is not installed
Filter Motor Error
ERROR
Pressure Sensor IC4811

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents