Electrical Adjustment
Grp Item Item Name
23
AV Cinema : LIMIT_CONTRAST
24
Auto Gamma CALC
25
PC Standard : CAL_CONT
26
PC Real
: CAL_CONT
27
AV Standard : CAL_CONT
28
AV Cinema : CAL_CONT
29
PC Standard : CONT_USE
30
PC Real
: CONT_USE
31
AV Standard : CONT_USE
32
AV Cinema : CONT_USE
991
Digital Gamma Test Pattern
Test Pattern Display
0
(No Last Memory)
OSD Gray Scale Red
1
(No Last Memory)
OSD Gray Scale Green
2
(No Last Memory)
OSD Gray Scale Blue
3
(No Last Memory)
Function
Auto-Gamma re-Calc when the value to 10
RESULT CONTRAST Read only
RESULT CONTRAST Read only
RESULT CONTRAST Read only
RESULT CONTRAST Read only
x0.001
x0.001
x0.001
x0.001
0000: Test Pattern Off
0001: OSD Gray Scale
0002: Window Pattern
0003: Vertical Gray Scale
0004: H-Stripe
0005: Diagonal Pattern
0006: Dot Pattern
-63-
Range
Initial
100 ~ 5000
1500
1 ~ 10
0
~
---
~
---
~
---
~
---
100 ~ 5000
500
100 ~ 5000
500
100 ~ 5000
500
100 ~ 5000
500
0 ~ 6
0
0 ~ 1023
960
0 ~ 1023
960
0 ~ 1023
960