Electrical Adjustment
Grp Item Item Name
149
Fan Clogged Setting
0
Temp C-A Upward High
1
Temp C-A Upward Low
2
Temp C-A Downward High
3
Temp C-A Downward Low
150
Shipping Setting
0
Shipping Setting
170
Wind Sensor
0
Flow Sensor Calibration
1
Flow Sensor Offset Min
2
Flow Sensor Offset Max
3
Flow Sensor Calibration Error Log
4
Clog Check Enable
171
Wind Sensor
0
Ideal Flow Data
1
Flow Difference Data
2
Clog Detect Flow Difference Data
3
Warn Detect Flow Difference Data
4
Press Add Data
5
Filter Scroll Timer
175
Filter
0
Compulsion Filter Taking Up
1
Take Up Bend
2
Take Up Times
3
Take Up Time Reset
4
Scroll Counter Reset Time
176
Filter Dispplay
0
Filter Icon Display
177
Filter Timer
0
Filter Timer Reset Times
1
Force Power Off Time
180
DDC Setting
0
HDCP EDID Data Setting
190
Panel Life Test
0
Panel Life enable
200
CXA7007
0
G SIG Center
1
B SIG Center
2
R SIG Center
3
G Gain Control
4
B Gain Control
5
R Gain Control
6
G Bright Control
7
B Bright Control
8
R Bright Control
9
G VCOM Control
10
B VCOM Control
11
R VCOM Control
Function
Fan voltage addition by Sensor A - C temp Upward High
Fan voltage addition by Sensor A - C temp Upward Low
Fan voltage addition by Sensor A - C temp Downward High
Fan voltage addition by Sensor A - C temp Downward Low
Shipping Set when the value is set to 10.
Wind Sensor Offset Auto-Calibration
Calibration starts when the value is set to 1. After calibration, OK is displayed.
Wind Sensor Mini Offset value
* After calibration, the value is set automatically.
(Offset Range: 350 - 550)
Wind Sensor Max Offset value
* After calibration, the value is set automatically.
(Offset Range: 550 - 800)
Error Log for Auto-Calibration
0: No Error
10: Min not stabilized
11: Min out of offset range
20: Max not stabilized
21: Max out of offset range
Clogged Detection (0: Disable / 1: Enable)
Airflow data theory for current fan voltage (Read only)
Differential value between actual and theory (Read only
"Differential value to judge "Clogged"(Read only)
"Differential value to judge "Clogged warning" (Read only)
Judge when the remaining scroll times is 0.
Additional value of press sensor
Filter scroll timer (hours)(Read only)
* Execute at 2000 hours
Filter scroll forcedly
*Execute when the value is set to 1
Remove flexure of filter
*Execute when the value is set to 1
Filter scroll remaining times (Read only)
Reset of scroll up times
*Reset when the value is set to 10.
Scroll Counter reset times (Read only)
Display 0: Disable / 1: Enable
Filter time reset times with user menu
Forced Power Off Time (hours)
0:DVI EDID Data / 1:HDCP EDID Data
0: Test Mode ON, Test Mode OFF
-48-
Range
Initial
0 ~ 1000
300
0 ~ 1000
280
0 ~ 1000
150
0 ~ 1000
110
0 ~ 10
0
0 ~ 1
0
0 ~ 1023
0
0 ~ 1023
0
0 ~ 1
Initial=0, Ship=1
-
-
-
-
-
-
-
-
-
-
-
-
0 ~ 1
0
0 ~ 1
0
-
9
0 ~ 10
0
0 ~ 255
0
0/1
1
0 ~ 255
0
0 ~ 1000
10
0 / 1
1
0 / 1
1
0 ~ 63
32
0 ~ 63
32
0 ~ 63
32
0 ~ 255
194
0 ~ 255
194
0 ~ 255
194
0 ~ 255
0
0 ~ 255
0
0 ~ 255
0
0 ~ 255
104
0 ~ 255
104
0 ~ 255
104