Sanyo PLC-XP100L Service Manual page 30

Hide thumbs Also See for PLC-XP100L:
Table of Contents

Advertisement

Optical Parts Disassembly
2-2 Polarized glasses-out removal
1 Remove 1 screw C (M.5x6) on each stopper and take
the polarized glasses upward off.
c
(Blue)
* Mount the glasses as the film
attached side comes to the LCD
panel side.
Note; Do not replace the LCD panel separately otherwise it cannot obtain
proper picture. Do not touch the prism, the LCD panel and electrode
of flexible cable.
IMPortANt NotIce on Lcd Panel/Prism Ass'y replacement
LCD panels used for this model cannot be replaced separately. Do not disassemble the LCD Panel/Prism Ass'y.
These LCD panels are installed with precision at the factory. When replacing the LCD panel, should be replaced
whole of the LCD panels and prism ass'y at once.
When replacing LCD Panel/Prism ass'y, take the optical and electrical adjustments following to the chapter "Ad-
justment".
Pre-Polarized glass (B)
Polarized glass-out (B)
-30-
c
Pre-Polarized glass (G)
Polarized glass-out (G)
c
Polarized glass-out (R)
(red)
(Green)
Pre-Polarized glass (R)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents