If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. C, the
machine will have a grounding plug that looks like the
plug illustrated in Fig. C. A temporary adapter, which
looks like the adapter illustrated in Fig. D, may be used to
connect this plug to a matching 2-conductor receptacle
as shown in Fig. D if a properly grounded outlet is not
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.
IN ALL CASES, MAKE CERTAIN THAT THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED.
IF YOU ARE NOT SURE, HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.
Fig. C
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

EXTENSION CORDS

EXTENSION CORDS
Use proper extension cords. Make sure
your extension cord is in good
condition and is a 3-wire extension cord which has a
3-prong grounding type plug and matching receptacle
which will accept the machine's plug. When using an
extension cord, be sure to use one heavy enough to
carry the current of the machine. An undersized cord
will cause a drop in line voltage, resulting in loss of
power and overheating. Fig. E shows the correct gauge
to use depending on the cord length. If in doubt, use
the next heavier gauge. The smaller the gauge number,
the heavier the cord.
FOREWORD
Model FS110L is a 10" Compound Power Laser Miter Saw designed to cut wood, plastic, and aluminum. Compound
angle and bevel cutting are easy and accurate. It can crosscut up to 5-5/8" x 2-3/4", miter at 45° both left and right 4"
x 2-3/4", bevel at 45° left 5-5/8" x 1-5/8", and compound 45° x 45°, 4" x 1-5/8". It has positive miter at 0°, 15.5°,
22.5°,30° and 45° both left and right, and bevel stops at 0° and 45° degrees adjustable.
Carefully unpack the machine and all loose items from the shipping container(s). Remove the protective coating from
all unpainted surfaces. This coating may be removed with a soft cloth moistened with kerosene (do not use acetone,
gasoline or lacquer thinner for this purpose). After cleaning, cover the unpainted surfaces with a good quality household
floor paste wax.
NOTICE: The manual cover photo illustrates the current production model. All other illustrations are
representative only and may not depict the actual color, labeling, or accessories, and are intended to
illustrated technique only.
Fig. E

FUNCTIONAL DESCRIPTION

UNPACKING AND CLEANING

6
available. The temporary adapter should be used only
until a properly grounded outlet can be installed by a
qualified electrician. The green-colored rigid ear, lug, and
the like, extending from the adapter must be connected
to a permanent ground such as a properly grounded
outlet box. Whenever the adapter is used, it must be
held in place with a metal screw.
Fig. D
GROUNDED OUTLET BOX
GROUNDING
MEANS
ADAPTER
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere
Total Length
Rating
Volts
of Cord in Feet
0-6
120
up to 25
0-6
120
25-50
0-6
120
50-100
0-6
120
100-150
6-10
120
up to 25
6-10
120
25-50
6-10
120
50-100
6-10
120
100-150
10-12
120
up to 25
10-12
120
25-50
10-12
120
50-100
10-12
120
100-150
12-16
120
up to 25
12-16
120
25-50
12-16
120
GREATER THAN 50 FEET NOT RECOMMENDED
Gauge of
Extension Cord
18 AWG
16 AWG
16 AWG
14 AWG
18 AWG
16 AWG
14 AWG
12 AWG
16 AWG
16 AWG
14 AWG
12 AWG
14 AWG
12 AWG