Check the appliance is electrically safe and gas sound when you have finished.
Fig.7.12
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
Fig.7.13
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
Fig.7.14
ArtNo.350-0012 - Securing the plinth
INSTALLATION
Electrical Connection
The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
The combined use of your induction cooker and other
domestic appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
6 mm² max
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
n
n
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
n
n
6 mm² max
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
10 mm² max
the mains cable to the correct terminals for your electrical
supply type (Fig.7.12 and Fig.7.13). Check that the links are
correctly fitted and that the terminal screws are tight. Secure
the mains cable using the cable clamp.
Final Checks
Hob Check
Check each cooking zone in turn. Be sure to use pans of the
correct size and material.
Grill Check
Turn on the grill control and check that the grill heats up.
Oven Check
Set the clock as described earlier, and then turn on the ovens.
Check the oven fans start to turn and that the ovens heat up.
Final Fitting
Fitting the Plinth
Loosen the 3 screws along the front bottom edge of the
cooker. Twist and fit each end keyhole over their respective
screws. Tighten the fixing screws (Fig.7.14).
Customer Care
Installer: Please complete your details in this guide, inform
the user how to operate the cooker and hand over the
instructions.
27
Current Operated Earth Leakage Breakers
Breaker with Overload).
ELECTRICIAN.
WARNING: THE APPLIANCE MUST BE EARTHED.
The cooker MUST NOT be connected to an ordinary
domestic power point.
Thank you.