DeWalt DXGN Series Instruction Manual page 13

Hide thumbs Also See for DXGN Series:
Table of Contents

Advertisement

Available languages

Available languages

GENERAL WATTAGE GUIDE
Item
Air Conditioner (12000 Btu) (*) . . . . . . . . . . . . . . . . . . .1750
Air Compressor (1/2 hp) (*) . . . . . . . . . . . . . . . . . . . . . .1400
Air Compressor (3/4 hp) (*) . . . . . . . . . . . . . . . . . . . . . .1800
Air Compressor (1 hp) (*) . . . . . . . . . . . . . . . . . . . . . . .2000
Battery Charger (25A) . . . . . . . . . . . . . . . . . . . . . . . . . . .600
Belt Sander (3" belt) . . . . . . . . . . . . . . . . . . . . . . . . . . .1000
Circular Saw (7 1/4") . . . . . . . . . . . . . . . . . . . . . . . 825-1050
Coffee Maker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900-1100
Edger (lawn) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .550
Furnace Fan (1/3 hp) (*) . . . . . . . . . . . . . . . . . . . . . . . . .1200
Hot Plate (single) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1500
Impact wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600
Light Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bulb rating
Nail Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1200
Microwave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .750
Paint Sprayer (1/3 hp) (*)
Paint Sprayer, hand-airless . . . . . . . . . . . . . . . . . . . . . . .175
Radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-200
Refrigerator (*) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600
Table Saw (10") (*) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2000
Television . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250-550
Weed Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500
Note: (*) Items allow at least 3 times the listed wattage for
starting.
NOTE: Many appliances such as saws or drills draw more
current than indicated on the manufacturer's nameplate when
under severe load.
STARTING THE GENERATOR SET
Before attempting to start the generator set, ensure that all
instructions given in previous sections have been followed
completely.
Check oil and fuel levels.
Turn the fuel shut-off valve on.
Move the choke lever on the front of the engine on. Note:
the choke may not be required when the engine is warm
or in high ambient temperatures.
Turn idle-control On/Off switch OFF.
RECOIL START
Move engine On/Off switch to On position.
Slowly pull recoil cord until resistance is felt and then pull
firmly. Let the recoil rewind slowly to avoid damage.
Return the choke to the original position.
ELECTRIC START (DXGN7200)
Move engine On/Off switch to On position.
Push and hold the On/Off switch in the Start position until
the engine starts and release. Note: If the engine does not
start after 5 seconds, stop and wait 10 seconds and repeat
this step.
Return the choke to the original position.
ELECTRIC START (DXGN14000)
Turn the key switch to "START". Release key switch after
the engine starts.
Return the choke to the original position.
English
Running Watts
. . . . . . . . . . . . . . . . . . . . . . . .650
CAUTION: This generator is equipped with an oil protection
system. When oil levels are too low for safe operation the
engine will shut down and/or will not start until the oil level is
corrected.
OPERATING THE GENERATOR SET
Once started, allow the engine to stabilize for approximately 3
minutes. Check that the circuit breakers and the GFCI
receptacles are not tripped. Turn the idle-control switch to the
On position if this feature is to be utilized. Set the voltage
selector switch to the appropriate mode, either 120V or
120/240V. See the guides below for more information on the
idle-control and voltage selector features.
IDLE CONTROL GUIDE (applicable models)
The automatic idle control system is available on some
generators. This feature allows the engine to automatically idle
down when there is no load drawn against the generator thus
saving fuel, decreasing wear and lowering the noise level.
There is an on-off switch located on the control panel that
activates or deactivates this feature. In the on position the
engine will idle down after detection of less than 40 Watts. The
engine will return to the correct running speed immediately
when a load of 350 Watts or more is applied. For applications
with loads less than 50W or with near constant loads, such as
home back up, it is best to turn the idle control feature off. The
feature should be turned off before starting or stopping the
generator and turned on when there will be extended periods
of inactivity for the generator.
Model DXGN14000: A 12V battery must be installed in
order for the idle control to function.
VOLTAGE SELECTOR GUIDE (applicable models)
The voltage selector switch allows the generator set to produce
120 volts only or to produce 120/240 volts simultaneously. With
the switch in the 120V position only the 120V receptacles may
be used. All of the power from the generator is available at 120
volts but the 240V output is not available. In the 120/240V
position all receptacles are operable however only half of the
generator output is available at any one 120V receptacle. Full
power may be pulled from the generator from the 240V
receptacle. The switch should always be left in the 120V
position when 240 volts are not needed. This balances the load
on the generator more effectively.
STOPPING THE GENERATOR SET
Unplug all appliances and let the engine run unloaded for a
couple of minutes. Turn the engine On/Off switch or key switch
to the Off position. Turn the fuel shut-off valve to the Off
position.
NOTICE:
Never use the choke to stop the engine.
13
0068660

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents