1-5-3. Self-diagnosis Code Table

Self-diagnosis Code
Block
Detailed
Function
Code
C
0
4
0
C
0
6
0
C
1
3
0
C
1
3
0
C
3
2
6
E
2
0
0
E
3
1
0
E
6
1
1
E
6
1
1
E
6
2
0
E
6
2
0
E
9
1
0
E
9
4
0
E
9
4
0
E
9
4
0
E
9
5
0
E
9
6
0
Note 1: Start the Adjust Manual in the Adjust Station and refer to the "DESTINATION DATA WRITE".
Note 2: Start the Adjust Manual in the Adjust Station and refer to the "INTERNAL MEMORY ADJUSTMENTS".
HDR-TG5/TG5E/TG5V/TG5VE/TG7VE_L2
Symptom/State
0
Non-standard battery is used.
0
The battery pack temperature is high.
"Memory Stick Duo" is unformatted.
1
"Memory Stick Duo" is broken.
2
Access error
Difficult to adjust focus
0
(Cannot initialize focus)
0
Flash memory data are rewritten.
0
Drive fault
Zoom operations fault
0
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
1
initialization of the zoom lens occurred
simultaneously.
Handshake correction function does not
0
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
1
work well. (With YAW angular velocity
sensor output stopped.)
Abnormality when flash is being
1
charged.
Fault of writing to or erasing the flash
0
memory
Internal memory is unformatted.
1
Internal memory is broken.
2
BGM data error
0
GPS hardware error
0
Map area mount error
Use the InfoLITHIUM battery.
Change the battery pack or place it in a cool place.
Format the "Memory Stick Duo".
Insert a new "Memory Stick Duo".
Remove the power source.
Reconnect it again and operate your camcorder again.
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin 1, 2 of
CN1003 on the VC-561 board). If it is OK, check the focus
motor drive IC (IC5201 on the VC-561 board).
Make flash memory data correct value. (Note 1)
Inspect or replacement of the internal memory (MS7308)
Inspect the lens block zoom reset sensor (pin wf of CN1003 on
the VC-561 board) when zooming is performed when the zoom
lever is operated, and the zoom motor drive circuit (IC5203 on
the VC-561 board) when zooming is not performed.
Check both C : 32 : 60 and E : 61 : 10 of the self-diagnosis code.
Inspect PITCH/YAW angular velocity sensors (SE6601 on the
GY-016 board) peripheral circuits.
Inspect PITCH/YAW angular velocity sensors (SE6601 on the
GY-016 board) peripheral circuits.
Checking of flash unit or replacement of flash unit.
Inspect the flash memory (IC2101 on the VC-561 board).
Format the internal memory (MS7308).
Insert a new internal memory (MS7308). (Note 2)
Inspect the flash memory (IC2101 on the VC-561 board). If it is
OK, check the CPU (IC1701 on the VC-561 board).
TG5V/TG5VE/TG7VE:
Check whether the flexible board of the GPS module is broken,
and check whether it is inserted imperfectly. If there is no
problem the flexible board, inspect or replacement of the GPS
module.
TG5V/TG5VE/TG7VE:
Inspect or replacement of the internal memory (MS7308).