Installation

Important: This thermostat must be installed according to all
national and local electrical codes. The installation must be
performed by qualified personnel.
Locating the floor temperature sensor
The floor temperature sensor is installed under the floor surface.
See the QuickNet System Installation Manual (H57704), Section
6, for more details. Perform the Sensor Resistance Test prior to
terminating the floor sensor to the thermostat. See the QuickNet
System Installation Manual (H57704), Section 7, for more details.

Wiring the thermostat

WARNING: Turn off the power to the circuit at the main
power panel to avoid electric shock.
WARNING: Shock hazard. To prevent shock, the QuickNet
floor heating mat must be connected to ground.
1. Remove the control module from the power base by loosening
the captive screw underneath the base.
2. Connect the floor heating cold leads to the load wires (two
inner wires) using the sup-
plied wire nuts.
3. Connect the power supply
leads to the power base wires
(two outer wires) using the
supplied wire nuts.
4. Connect the floor heating cold
lead braid (ground) to the
supply ground in the electrical
junction box.
THERMAL MANAGEMENT SOLUTIONS
Air
vents
Control
module
Air
vents
Power
supply
Load / Floor heating mat
ML-RaychemQuickStatTCthermostat-IM-H58517      01/13
5. Insert the floor sensor cable through one of the two openings
on the power base and connect to terminals 1 and 2 (no polar-
ity). Position the sensor cable such that it does not come in
contact with the floor heating wires.
6. Push the excess length of the wires back inside the electrical
junction box
7. Secure the power base to the electrical junction box using the
provided mounting screws
8. Verify the settings of the configuration switches on the back
of the control module. Default settings for the configuration
switches are highlighted below.
Important: If your system is installed underneath laminate
or engineered wood flooring, you MUST use AF mode with the
default settings. Note the factory default is AF mode.
Power
base
No.
Configuration
1
Display format
2
Early Start
Supply
3
Temperature control mode
ground
1
Early Start can be used in Automatic mode only. When this
Floor
heating
function is enabled, the thermostat calculates the optimal time
cold lead
to start heating in order to obtain the desired temperature by the
ground
set time. The thermostat re-assesses the start time daily based
on the previous day's results.
Note: If you wish to use only 2 periods, set periods "1 and 4"
or periods "2 and 3". Early Start will not work if you set periods
"1 and 2" or periods "3 and 4".
2
To select floor sensing mode, place the switch to the F position.
To select floor sensing and ambient sensing mode, place the
switch to the AF position and ensure that the remote tempera-
ture sensor is connected to the thermostat. To select the A
mode, place the switch in the AF position and ensure that the
remote temperature sensor is NOT connected to the thermostat.
9. Install the control module onto the power base.
Floor temperature sensor
Up
°F/12 hr
Enable
1
F
2
Supply
ground
Floor
heating
cold lead
ground
Down
°C/24 hr
Disable
AF
2 / 6