Bryant 180B Product Data page 11

2-5 ton evolution 20 air conditioner with puron refrigerant
Hide thumbs Also See for 180B:
Table of Contents

Advertisement

TESTED AHRI COMBINATION RATINGS
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory
Additional ratings and system combinations can be accessed via the Bryant database at:
http://cactaxcredits.info/bryant-ratings/hp_ratings_srch.php
Equipment performance calculator can be accessed at:
Model Number
180BNA024****A
180BNA036****B
180BNA048****A
180BNA060****A
* AHRI = Air Conditioning, Heating & Refrigeration Institute
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
TDR — Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause
degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are
equipped with TDR.
UI
— User Interface
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations
are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.
http://rpmobbry.wrightsoft.com/
Indoor Coil Model
Furnace Model Number
Number
FE5ANB004+UI
FE5ANB004+UI
FE4ANB006+UI
FE4ANB006+UI
www.ahridirectory.org
AHRI Standard Ratings --- Cooling
Cooling
EER
Capacity
26,600
15.0
37,000
14.6
48,000
13.5
59,000
13.1
11
ID CFM
SEER
High
Low
21.0
800
800
20.0
1200
925
18.0
1400
1120
16.7
1750
1400