Marketing on 0845 121 7400. Certification Mark Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
3.5 Typical Fully Pumped System with 3-Port Mid-Position Valve ....................10 3.6 Typical Fully Pumped System with Spring Return Zone Valve in each Service ..............11 3.7 Typical Fully Pumped System with Fully Motorised Zone Valve in each Service ............12 4.0 Replacement ..................... 13 Danfoss Heating...
1.0 Installation Guide Please Note: This product should only be installed by a qualifi ed electrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations. 2.0 System Overview Specifi cation Power supply 230 ±...
Page 5
10. Then press both WATER and HEATING rocker switches to the OFF position and check that both services do not operate. 11. Finally, press both WATER and HEATING rocker switches to TIMED position prior to programming the unit. Danfoss Heating...
3.1 Wiring Typical wiring diagrams for various types of systems are shown on the following pages. Note: Whilst every attempt has been made to ensure the accuracy of this information it is recommended that the specifi c information relating to the ancillary controls is obtained from the manufacturers concerned.
Cyl. Room Stat Stat Boiler S.R.Z.V & Pump in HTG Other Danfoss Randall products suitable for use with above circuit:- AT cylinder thermostat; 2 x HP22 or HP28 motorised zone valve with spring return actuator and SPST auxiliary switch. SET3E...
Supply 3 amp fuse Cyl. Room Stat Stat S.R.Z.V Boiler Pump in DHW Other Danfoss Randall products suitable for use with above circuit:- AT cylinder thermostat; HP28C motorised zone valve with spring return actuator and SPDT auxiliary switch. Danfoss Heating...
Terminals Mains Links Supply 3 amp fuse Cyl. Room Stat Stat 3-port Boiler mid pos & Pump valve Other Danfoss Randall products suitable for use with above circuit:- AT cylinder thermostat HS3 3-port mid-position valve with spring return actuator. SET3E...
Stat Stat S.R.Z.V. S.R.Z.V. Boiler in DHW in HTG Other Danfoss Randall products suitable for use with above circuit:- AT cylinder thermostat 2 x HP22 or HP28 motorised zone valve with spring return actuator and SPST auxiliary switch Danfoss Heating...
Motorised Zone Valve in each Service D.H.W. Programmer Terminals Mains Supply Links 3 amp fuse Cyl. Room Stat Stat F.M.Z.V F.M.Z.V Boiler in DHW in HTG Other Danfoss Randall products suitable for use with above circuit:- AT cylinder thermostat. SET3E...
If there is any doubt about the way in which the existing programmer is connected, please contact our Technical Services Department before proceeding with replacement. Note: The SET3E is a direct plug-in replacement for a Danfoss Randall SET5, although it does not off er 5/2 day programming option.