Kohler AEGIS LH630 Service Manual page 147

Liquid-cooled horizontal crankshaft
Hide thumbs Also See for AEGIS LH630:
Table of Contents

Advertisement

Section 11
Reassembly
Figure 11-28. Crankcase Vacuum Fitting Position.
Install Hydraulic Lifters
1. Lubricate the lifters and lifter bores in the
crankcase with engine oil.
NOTE: Hydraulic lifters should always be
installed in the same position as before
disassembly.
2. Install the lifters into their respective lifter bores
according to location and cylinder number marked
during assembly. See Figure 11-29.
Figure 11-29. Installing Lifters.
Valve Stem Seals
NOTE: These engines use valve stem seals on the
intake valves. Always use a new seal before
valves are installed in the cylinder head. Also,
replace the seals if they are deteriorated or
damaged in any way. Never reuse an old seal.
See Figure 11-30.
11.10
www.SmallEngineDiscount.com
Intake Seal
Figure 11-30. Cylinder Head Showing Intake Seal.
Assemble Cylinder Heads
Prior to installation, lubricate all components with
engine oil, paying particular attention to the lip of the
valve stem seal, valve stems and valve guides. Install
the following items in the order listed below using a
valve spring compressor. See Figures 11-31 and 11-32.
Valve stem seals (intake valve only)
Intake and exhaust valves
Valve spring caps
Valve springs
Valve spring retainers
Valve spring keepers
Figure 11-31. Disassembled Head and Valve
Components.