WARNING: If not installed, operated and main-
tained in accordance with the manufacturer's
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
— Do not store or use gasoline or other flamma-
— WHAT TO DO IF YOU SMELL GAS
— Installation and service must be performed by
AND
FAN TYPE
VENTED
WALL FURNACE
MODEL
FAW-55SPP
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
ble vapors and liquids in the vicinity of this or
any other appliance.
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
If you cannot reach your gas supplier, call
the fire department.
a qualified installer, service agency or the gas
supplier.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Heating Systems FAW-55SPP

  • Page 1: Installation Instructions

    OWNER’S MANUAL FAN TYPE VENTED WALL FURNACE MODEL FAW-55SPP WARNING: If the information in these instruc- tions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 Specifications This series is design certified in accordance with American National Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian Model FAW-55SPP Standards Association, as a Fan Type Vented Wall Furnace and Input BTU/HR (KW/H) 55,000 (16.1) must be installed according to these instructions.
  • Page 3: Safety Information For Users Of Lp-Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires point with the members of your household. Someday, when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone’s safety will de- colorless.
  • Page 4 Ventilation and Combustion Air the main burners to “shut off.” Wall furnaces shall be installed in a location in which the facilities for Refer to Figure 1 and Page 12 for additional information regarding U.L. ventilation permit satisfactory combustion of gas and proper venting Listed gas vent equipment.
  • Page 5 8” x 12” (203mm x 305mm) boot. Remove duct and cut to proper length. 8. Attach 6” x 10” (152mm x 254mm) duct to inner casing with (6) 4” (102mm) MINIMUM 4” (102mm) MINIMUM #10 x 1/2” (13mm) screws provided. TO COMBUSTIBLES TO COMBUSTIBLES 9.
  • Page 6 (914mm) plug assembly. Insert 7/8” (22mm) strain relief bushing –ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than into the 7/8” (22mm) hole in the side panel. All-Metal Constructions The above connectors may be used if acceptable by the authority having Attention! The 7/8”...
  • Page 7 On a new installation with air in the gas line, it is suggested that a match Wiring be used. The match will light the pilot faster than the piezo under this The appliance, when installed, must be electrically grounded in accor- condition.
  • Page 8 4. Type of gas being used and that shown on the rating label. to “shut off” due to improper venting or a blocked flue. The Service Department at Empire Comfort Systems, Inc. may be contacted To reset the manual reset vent safety switch: to assist in servicing furnace.
  • Page 9: For Your Safety Read Before Lighting

    FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. •If you cannot reach your gas supplier, call the fire When lighting the pilot, follow these instructions exactly.
  • Page 10 Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 Page 10...
  • Page 11 12428-6-0408 Page 11...
  • Page 12 Vent enclosure, 36” (914mm) [for rooms up to 118 1/2” (301cm) in height] DV-648 4” (102mm) Oval-to-Round flue adapter kit Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com.