Empire Heating Systems FAW-55SPP Installation Instructions And Owner's Manual

Empire Heating Systems FAW-55SPP Installation Instructions And Owner's Manual

Fan type vented wall furnace
Hide thumbs Also See for FAW-55SPP:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer's
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
— Do not store or use gasoline or other flamma-
— WHAT TO DO IF YOU SMELL GAS
— Installation and service must be performed by
AND
FAN TYPE
VENTED
WALL FURNACE
MODEL
FAW-55SPP
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
ble vapors and liquids in the vicinity of this or
any other appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
• If you cannot reach your gas supplier, call
the fire department.
a qualified installer, service agency or the gas
supplier.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Heating Systems FAW-55SPP

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS OWNER’S MANUAL FAN TYPE VENTED WALL FURNACE MODEL FAW-55SPP WARNING: If the information in these instruc- tions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 General Information Specifications This series is design certified in accordance with A merican National Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian Model FAW-55SPP Standards Association, as a Fan Type Vented Wall Furnace and Input BTU/HR (KW/H) 55,000 (16.1) must be installed according to these instructions. Height 82 3/8”...
  • Page 3: Safety Information For Users Of Lp-Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires point with the members of your household. Someday, when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone’s safety will de- colorless. You may not know all the following safety precau- pend on knowing exactly what to do.
  • Page 4 Ventilation and Combustion Air the main burners to “shut off.” Wall furnaces shall be installed in a location in which the facilities for Refer to Figure 1 and Page 12 for additional information regarding U.L. ventilation permit satisfactory combustion of gas and proper venting Listed gas vent equipment. under normal conditions. In buildings of conventional frame, brick, or Installing Optional Side Outlets stone construction without tight storm windows and doors, infiltration Side outlet register, SOR-1 may be installed on one or both sides of the is normally adequate to provide air for combustion and draft hood dilu- furnace at the required clearances of 18 inches (457mm) to adjacent wall...
  • Page 5 8” x 12” (203mm x 305mm) boot. Remove duct and cut to proper length. 8. Attach 6” x 10” (152mm x 254mm) duct to inner casing with (6) 4” (102mm) MINIMUM 4” (102mm) MINIMUM #10 x 1/2” (13mm) screws provided. TO COMBUSTIBLES TO COMBUSTIBLES 9.
  • Page 6 (914mm) plug assembly. Insert 7/8” (22mm) strain relief bushing –ANS Z21.45 A ssembled Flexible A ppliance Connectors of Other Than into the 7/8” (22mm) hole in the side panel. All-Metal Constructions The above connectors may be used if acceptable by the authority having Attention! The 7/8” (22mm) strain relief bushing is located within the same jurisdiction.
  • Page 7 On a new installation with air in the gas line, it is suggested that a match Wiring be used. The match will light the pilot faster than the piezo under this The appliance, when installed, must be electrically grounded in accor- condition.
  • Page 8 3. The 24 volt system manual reset vent safety switch will cause gas flow to the main burners 4. Type of gas being used and that shown on the rating label. to “shut off” due to improper venting or a blocked flue. The Service Department at Empire Comfort Systems, Inc. may be contacted To reset the manual reset vent safety switch: to assist in servicing furnace. 1. Remove upper front panel. 2. Depress red manual reset button. The manual reset vent safety switch Servicing the Pilot and Main Burners, Pilot Orifice, Thermocouple, is located on the draft diverter.
  • Page 9: For Your Safety Read Before Lighting

    FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. •If you cannot reach your gas supplier, call the fire When lighting the pilot, follow these instructions exactly. department. B. BEFORE LIGHTING smell all around the appliance area C.
  • Page 10 Be sure to give all this information... Furnace Model Number Part Description Furnace Serial Number Part Number Type of Gas (Propane or Natural) Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 Page 10 12428-7-1109...
  • Page 11 12428-7-1109 Page 11...
  • Page 12 106 1/2” (270.5cm) in height] DV-666 Vent enclosure, 36” (914mm) [for rooms up to 118 1/2” (301cm) in height] DV-648 4” (102mm) Oval-to-Round flue adapter kit Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer.
  • Page 13 MAnUEL DU PRoPRIéTAIRE RADIATEUR MURAL à cIRcULATIon foRcéE ET AvEc évAcUATIon MoDèLE fAW-55SPP AVERTISSEMENT: Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
  • Page 14 Standard / cSA Standard Z21.86 et cSA 2.32 par canadian Standards Association comme étant un radiateur mural à circulation forcée et avec Modèle fAW-55SPP évacuation, devant être installé en accordance avec ces instructions. Tout changement du modèle d’origine, installé autrement que décrit Puissance BTU/H (KW/H) 55,000 (16.1)
  • Page 15: Information De Sécurité Pour Les Utilisateurs De Propane

    InfoRMATIon DE SécURITé PoUR LES UTILISATEURS DE PRoPAnE Le propane est un gaz inflammable qui peut causer des feux et des n’y aura pas une minute à perdre, la sécurité de chacun dépendra de explosions. Dans son état naturel, le propane est inodore et sans couleur. votre savoir-faire.
  • Page 16 Air de ventilation et de combustion Installation des Sorties Optionnelles Sur les Côtés Les radiateurs muraux doivent être installés dans un endroit où la facilité Le registre avec sortie sur le côté, SOR-1, peut être installé sur un ou les de la ventilation permet une combustion de gaz satisfaisante et un échappe- deux côtés du radiateur pourvu que les espaces libres de 18"...
  • Page 17 CONNEXION OVALE DE 5. Aligner les trous libres de la hotte de 8" x 12" (203mm x 305mm) CHEMINEE DE TYPE “B” de 4” (102MM) L’ÉSPACE LIBRE DU CENTRE DE avec les trous de vis de la paroi extérieure arrière et marquer la hotte L’ÉVENT AUX COMBUSTIBLES EST DE 9/16”...
  • Page 18 Emplacement de l'Alimentation électrique Sur le bas des panneaux des côtés gauche et droit, il y a une entrée défon- BONDE NPT DE 1/8” (3MM) POUR VÉRIFIER LE JAUGEAGE DES çable de 7/8" (22mm) de diamètre. L’assemblage de la fiche à trois broches CONNEXIONS TUYAU D’ALIMENTATION EN GAZ (prise de terre) est situé...
  • Page 19 Aspect convenable de la flamme du Brûleur Principal VALVE VUE DE DESSUS La flamme convenable aura une petite flamme bleue intérieure avec une RÉGULATOR DE PRESSION flamme extérieure bleue pâle beaucoup plus grande. Le brûleur principal ÉVENT (figure 7) représente la hauteur approximative pour chaque partie de la PRISE POUR SORTIE ClÉ...
  • Page 20 L’enceinte de l’évent Isolée. Si l’interrupteur de sûreté de l’évent avec remise à zéro manuelle continu Les radiateurs muraux avec un évent, installés dans des bâtiments ay- d’arrêter le débit de gaz aux brûleurs principaux, un technicien d’entretien ant un toit plat, peuvent avoir une évacuation inadéquate. Lorsque le qualifié...
  • Page 21: Instructions D'allumage

    PoUR voTRE SécURITé, LIRE AvAnT D’ALLUMER AvERTISSEMEnT: Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. cet appareil a une veilleuse qui doit être allumée manuellement. •...
  • Page 22: Suggestions Pour Le Service Et L'entretien

    Pour vous assister à l’entretien du radiateur, vous pouvez contacter le d’araignées. Nettoyer l’assemblage de la veilleuse et réallumer. département de service à Empire Comfort Systems, Inc. La veilleuse s’enflamme mais s’éteint lorsque le bouton est relâché: Entretien de la veilleuse et des brûleurs principaux, ouverture de la 1.
  • Page 23 S’IL voUS PLAîT noTER: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. numéro numéro Index Part d’Index de la Pièce number Description Description WfA-115 Joint d’étanchéité de la plaque de base 712045 Joint d’étanchéité...
  • Page 24 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 Page 12 12428-6-1109...
  • Page 25 L’évacuation du modèle fAW-55 peut se faire comme il est représenté. Le capuchon d’évent doit être à au moins 12' (3.7m) au-dessus du plancher. Les entretoises fixes du tuyau d’évent B-1 gardent l’espace libre aux constructions combustibles à 1" (25mm). L’installation doit être conforme aux codes locaux.
  • Page 26 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com...

Table of Contents