Miele KF 1801 Vi Operating And Installation Instructions page 55

Miele fridge freezer operating and installation instructions
Table of Contents

Advertisement

. . . the ice cube maker is producing
too few or misshapen ice cubes.
^ Check whether there is sufficient
water pressure. The water pressure
(flow rate) must be between 1.7 and
5.5 bar.
^ Check that the temperature in the
freezer zone is low enough.
^ Change the water filter.
. . . water is pouring out of the
appliance.
^ Close the stopcock immediately.
^ Check whether the water pipework
inside the appliance is damaged.
Call the Service Department.
^ Check whether there is sufficient
water pressure.
^ Check whether the correct valve was
fitted.
. . . "_F" and "121" appear alternately
in the temperature display.
The ice cube maker is not connected to
the mains water supply.
^ Check whether the appliance is
correctly connected to the mains
water supply.
^ Check whether the stopcock is open.
. . . Another fault message with "_F"
appears in the temperature display.
There is a fault. Call the Service
Department.
Problem solving guide
. . . the interior lighting is not
working.
Has the appliance door been left open
for too long? To avoid overheating, the
lighting switches itself off automatically
after approx. 5 minutes if the door is left
open. It will come on again after it has
cooled down sufficiently.
If it does not come on when the door is
opened briefly, then the lighting is
defective.
^ Switch the appliance off by pressing
the On/Off rocker switch to the right
hand side underneath the control
panel.
^ Disconnect the appliance from the
mains electricity supply.
Top lighting
^ Hold the lamp cover at the front with
both hands and push it back.
^ Then lift the lamp cover forwards to
remove.
Do not touch halogen lamps with
your bare fingers.
Use a soft cloth when changing a
halogen lamp.
55