Wiring Diagram; Wired Remote - Mitsubishi Electric Mr.SLIM PCA-RP50KAQ Service Manual

Series pca split-type, heat pump air conditioners
Hide thumbs Also See for Mr.SLIM PCA-RP50KAQ:
Table of Contents

Advertisement

8

WIRING DIAGRAM

PCA-RP35KAQ
PCA-RP100KAQ
PCA-RP50KAQR1
[LEGEND]
SYMBOL
NAME
I.B
INDOOR CONTROLLER BOARD
CN2L
CONNECTOR (LOSSNAY)
CN32
CONNECTOR (REMOTE SWITCH)
CN41
CONNECTOR (HA TERMINAL-A)
CN51
CONNECTOR (CENTRALLY CONTROL)
FUSE
FUSE (T6.3AL250V)
LED1
POWER SUPPLY (I.B)
LED2
POWER SUPPLY (R.B)
LED3
TRANSMISSION (INDOOR-OUTDOOR)
SW1
SWITCH (MODEL SELECTION)
SW2
SWITCH (CAPACITY CODE)
SWE
CONNECTOR (EMERGENCY OPERATION)
X1
RELAY (DRAIN PUMP)
R.B
WIRED REMOTE CONTROLLER BOARD
DCL
REACTOR
MF
FAN MOTOR
MV
VANE MOTOR
TB2
TERMINAL BLOCK (Indoor unit Power (option parts))
I.B
VANE CNV(WHT)
20
18
16
14
12
10
8
6
4
19
17
15
13
11
9
7
5
3
WIRELESS
CN90
(WHT)
1
9
CNB
BZ
5
SW1
LED2
M
SW2
LED1
RU
MV
W.B
(OPTION PARTS)
Notes: 1. SymboIs used in wiring diagram above are,
:Terminal (block).
2. Indoor and outdoor connecting wires are made with poIarities,
make wiring matching terminal numbers (S1, S2, S3).
3. Since the outdoor side electric wiring may change, be sure to
check the outdoor unit electric wiring for servicing.
4. This diagram shows the wiring of indoor and outdoor connecting
wires.(specification of 230V), adopting superimposed system
of power and signal.
*1: When work to Supply power separately to indoor and
outdoor units was applied, refer to Fig 1.
*2: For power supply system of this unit, refer to the caution
label located near this diagram.
OCH491C
PCA-RP50KAQ
PCA-RP125KAQ
PCA-RP60KAQR1
SYMBOL
TB4
TERMINAL BLOCK (INDOOR/OUTDOOR CONNECTING LINE)
TERMINAL BLOCK (REMOTE CONTROLLER
TB5,TB6
TRANSMISSION LINE)
TH1
ROOM TEMP. THERMISTOR
(0ºC / 15kΩ, 25ºC / 5. 4kΩ DETECT)
TH2
PIPE TEMP. THERMISTOR/LIQUID
(0ºC / 15kΩ, 25ºC / 5. 4kΩ DETECT)
TH5
COND. / EVA. TEMP. THERMISTOR
(0ºC / 15kΩ, 25ºC / 5. 4kΩ DETECT)
See table 1
OPTION PARTS
See table 2
W.B
PCB FOR WIRELESS REMOTE CONTROLLER
BZ
BUZZER
LED1
LED (OPERATION INDICATION : GREEN)
LED2
LED (PREPARATION FOR HEATING : ORANGE)
RECEIVING UNIT
RU
SW1
EMERGENCY OPERATION (HEAT / DOWN)
SW2
EMERGENCY OPERATION (COOL / UP)
DP
DRAIN PUMP
FS
DRAIN FLOAT SWITCH
Refer to tables 1 and 2
J41
J42
CN32
SW1
SW2
2
(WHT)
CN51(WHT)
1
Pair No.
5
CN41(WHT)
CN2L
2 1
4
LED3
LED2
LED1
SWE
ON OFF
FLOAT SW
CN4F
(WHT)
9
1
4
When attaching
When attaching
drain pump
drain pump
(option parts),
(option parts)
remove the jumper
connector CN4F
1
and fit the drain
FLOAT SW
CN4F
float switch (FS).
(WHT)
: Connector,
PCA-RP60KAQ
PCA-RP140KAQ
PCA-RP71KAQR1
The black square(■)indicates a switch
NAME
position.
<Table 1>
SW1 (MODEL SELECTION)
<Table 2>SW2 (CAPACITY CODE)
PCA-RP35KAQ
PCA-RP50KAQ
PCA-RP60KAQ
PCA-RP71KAQ
(OPTION PARTS)
TB5
2
1
1
2
TB6
2
R.B
OUTDOOR
1
3
1 3
INDOOR/OUTDOOR
COMMUNICATION
1
CN3C
(BLU)
1
2
+
REMOCON
1
CN22
(BLU)
LIQUID/PIPE
INTAKE
FAN
CNMF
CN44
CN20
(WHT)
(RED)
(WHT
)
1
4
1
2
7
4
MS
3~
TH2 TH5
TH1
MF
4
*Be sure to turn off the source power
and then disconnect fan motor connector.
FS
(Failure to do so will cause trouble in fan motor)
DCL
*1 (Fig. 1)
CN01
I.B
(BLK)
YLW
5
3
1
I.B
INDOOR/OUTDOOR
1
3
CN3C
COMMUNICATION
(BLU)
19
19
PCA-RP71KAQ
SW1
Service
1 2 3 4 5
ON
OFF
SW2
MODELS
Service
MODELS
1 2 3 4 5
PCA-RP100KAQ
ON
OFF
1 2 3 4 5
ON
PCA-RP125KAQ
OFF
1 2 3 4 5
PCA-RP140KAQ
ON
OFF
1 2 3 4 5
ON
OFF
TRANSMISSION
DCL
WIRES
DC12V
YLW
1 3 5
CN01
(BLK)
FUSE
TB4
YLW
YLW
S1
ORN
ORN
X1
S2
S3
D.U.M
3
1
1
ORN
CNP
BRN
(BLU)
M
1~
DP
(OPTION PARTS)
TB2
YLW
RED
L
POWER SUPPLY
ORN
BLU
N
(1PHASE)
GRN/YLW
230V 50Hz
TB4
YLW
S1
ORN
ORN
S2
TO OUTDOOR UNIT
BRN
S3
Service
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
TO OUTDOOR
UNIT