7-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and conduct dielectric strength test.
Insulation resistance: 7 M Ω or more with DC 500 V megohm tester
Dielectric strength: AC 4,000 V/1 minute, with no abnormalities
AC 2,500 V/1 minute, with no abnormalities
7-7. No-load Current Value
After no-load operation for 30 minutes, the current value in the case of operation with the nozzle should be as
follows.
Voltage
Current
110 V
220 V
5.2 A
2.6 A
220 V --- 240 V
• • • • • • •
(and 110 V for U. K. products)
110 V
• • • • • • •
(except for U. K. products)
230 V
240 V
2.5 A
2.4 A
--- 10 ---