7.4.2
Voltage Calibration
1.
Enter Test-Set mode in Service Channel Box.
2.
Press F4 and select VIEW ADC LINES.
3.
Observe the ADIN1 value. This value is BAT VOLT HIGH. If this reading is outside the range 564 - 664, then there is a
fault and further investigation is required. Otherwise, record this value for later use.
MCUK010801C8
Service Manual
Section 7
– 45 –
ADJUSTMENT PROCEDURES
Revision 0
Issue 1