Installation

When building in the appliance,
ensure that the vents at the front of
the appliances are not obstructed or
blocked by any objects.
Make sure that there is a gap of at
least 2.5 mm between the sides of
the appliance and adjoining furniture
doors and at least 4 mm above the
appliance.
The appliance can fit into a 350 mm
high niche in a tall unit or a wall unit, or
a 360 mm high niche in a tall unit.
Building-in dimensions
M 8161-2
58
For safety reasons, do not build the
appliance into a wall unit that is
directly above a hob.
A minimum installation height of
850 mm must be maintained.
To transport the appliance, make
sure that you lift it by the appliance
housing and not by the frame. The
frame is not sturdy enough to bear
the weight of the appliance when it
is being carried.