Installation Place; Electrical Work - Mitsubishi Electric MSC-GE20VB Operating Instructions Manual

Split-type air conditioners
Hide thumbs Also See for MSC-GE20VB:
Table of Contents

Advertisement

Available languages

Available languages

● OPERATING INSTRUCTIONS ●
W
HEN THE AIR IS NOT GOING TO BE
USED FOR A LONG TIME
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours.
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to growth of fungi, such as
mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter.
Page 7
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
S
PECIFICATIONS
Set name
Indoor
Model
Outdoor
Function
Cooling
Power supply
Capacity
kW
Input
kW
0.715
Indoor
kg
Weight
Outdoor
kg
Refrigerant fi lling capacity
kg
(R410A)
Indoor
IP code
Outdoor
Permissible
LP ps
MPa
excessive
operating
HP ps
MPa
pressure
Indoor
(High/Med./
dB(A)
Noise
level
Low)
Outdoor
dB(A)
Guaranteed operating range
Indoor
32°C DB
Upper limit
23°C WB
Cooling
21°C DB
Lower limit
15°C WB
27°C DB
Upper limit
Heating
20°C DB
Lower limit
En-9
Page 4
MSH-GE20VB
MSH-GE25VB
MSC-GE20VB
MSC-GE25VB
MUH-GA20VB
MUH-GA25VB
(-E1/E2)
(-E1/E2/E3)
Heating
Cooling
Heating
2.3
2.5
2.65
3.0
0.69
0.82
0.82
9
32/29
32/30/34
0.65/0.60
0.80/0.65/0.95
36/31/25
36/31/25 39/32/25 40/33/26 39/33/26
47
Outdoor
43°C DB
21°C DB
24°C DB
18°C WB
-10°C DB
DB: Dry Bulb
-11°C WB
WB: Wet Bulb
I
NSTALLATION PLACE AND

ELECTRICAL WORK

Installation place

Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as a hot spring.
• Where oil is splashed or where the area is fi lled with oily smoke.
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit does not bother the
house next door.
To prevent the effects
of a fl uorescent lamp,
keep as far apart as
possible.
1 m
or more
1 m
or more
Cordless
phone or
Portable
phone
Radio
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
MSH-GE35VB
MS-GE20VB
MSC-GE35VB
MSC-GE20VB
MUH-GA35VB
MU-GA20VB
(-E1/E3)
(-E1/E2/E3)
Cooling
Heating
Cooling
~ /N, 230 V, 50 Hz
3.5
3.7
2.3
1.09
1.02
0.715
10
35/39
31/27/PENDING
0.80/1.05
0.60/0.60/PENDING
IP 20
IP 24
1.64
4.15
49
Note:
Rating condition
Cooling — Indoor:
Outdoor: 35°C DB
Heating — Indoor:
Outdoor: 7°C DB, 6°C WB
The installation location of the outdoor unit should
be at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
Inverter-type
fl uorescent lamp
Well-
ventilated dry
place
Keep a space to
prevent the pic-
ture distortion or
100 mm or
the noise.
more
200 mm
TV
or more
3 m or
more
MS-GE25VB
MS-GE35VB
MSC-GE25VB
MSC-GE35VB
MU-GA25VB
MU-GA35VB
(-E1/E2)
(-E1/E2/E3)
Cooling
Cooling
2.5
0.775
9
31/27
30/34/PENDING
0.60/0.60
0.70/0.90/PENDING
36/31/25
40/33/26
45
27°C DB, 19°C WB
20°C DB
wall, etc.
3.45
1.12
10
49