When The Air Conditioner Is Not Going To Be Used For A Long Time; Installation Place And Electrical Work - Mitsubishi Electric Mr.SLIM MSY-JY09VF Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

W
HEN THE AIR CONDITIONER ISNOT
GOING TO BE USED FOR A LONG TIME
1
Operate by COOL mode with the
highest temperature set or FAN
mode for 3 to 4 hours.
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to
growth of fungi, such as mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or discon-
nect the power supply plug.
4
Remove all batteries from the remote
controller.
When using the air conditioner
again:
1
Clean the air fi lter.
2
Check that the air inlet and outlet of
the indoor and outdoor units are not
blocked.
3
Check that the earth is connected
correctly.
4
Refer to the "PREPARATION BE-
FORE OPERATION", and follow the
instructions.
Page 7
Page 8
Page 12
I
NSTALLATION PLACE
AND ELECTRICAL WORK
Installation place
Avoid installing the air conditioner in the following
places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as hot spring,
sewage, waste water.
• Where oil is splashed or where the area is fi lled with
oily smoke (such as cooking areas and factories, in
which the properties of plastic could be changed and
damaged).
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit
bothers the house next door.
• The mounting height of indoor unit 1.8 m to 2.3 m is
recommended. If it is impossible, please consult your
dealer.
• The indoor unit must be installed in rooms which
exceed the fl oor space specifi ed. Please consult your
dealer.
• Do not operate the air conditioner during interior
construction and fi nishing work, or while waxing the
fl oor. Before operating the air conditioner, ventilate the
room well after such work is performed. Otherwise, it
may cause volatile elements to adhere inside the air
conditioner, resulting in water leakage or scattering of
dew.
The installation location of the outdoor unit should be
at least 3 m away from the antennas for TV sets, ra-
dios, etc. In areas where the reception is weak, pro-
vide greater space between the outdoor unit and the
antenna of the aff ected device if operation of the air
conditioner interferes with radio or TV reception.
Inverter-type
To prevent the eff ects
fl uorescent lamp
of a fl uorescent lamp,
keep as far apart as
possible.
Keep a space
to prevent
the picture
distortion or
1 m or
the noise.
more
1 m or
Cordless
more
phone or
Portable
Radio
phone
Electrical work
• Provide an exclusive circuit for the power supply of the
air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
wall, etc.
For the optimum effi -
ciency and to extend
the life time of using,
the outdoor unit
should be installed
in a well-ventilated
dry place.
100 mm or
(JY09, 13, 15/
more
JY18/JY24)
100/200/500 mm
TV
or more
3 m or more
En-18