Specifications

Model name
Running current (A)
GUG-01SL-E
GUG-02SL-E
Less than 0.1 A
GUG-03SL-E
* The running current and the input power are based on 230V/50Hz.

Relocation, installation place

■ Moving the Unit
(1) When removing and re-installing the unit for extension and reconstruction or for moving to another site, contact your dealer in advance.
Specialised skills for moving the unit will be required. Construction expenses will be incurred.
(2) When the unit is filled with refrigerant during installation or when it is moved, do not use refrigerants other than designated.
(3) Handling of freon gas or abandonment of this unit, follow local regulations or standards.
■Installation Site
(1) When installing or moving the unit, contact your dealer or specialist vendor.
(2) Avoid installation at the following sites: described in
(3) Install the unit so that it is horizontal or a drain discharge port is attached below (within 1 °). Otherwise, water may drip.
(4) When installing the unit in places such as hospitals or communications service stations, take necessary measures to shield noise generating
sources.

Maintenance and lifetime

The parts listed below are service parts. It is necessary that the regular check and the regular replacement or the replacement when it is broken. In
addition, expenses for parts and replacement work is charged to customers.
- Drain pump
- Printed circuit board

After-sales servicing

Consult with your dealer about the after-sales services provided for
this product.
Inspect your unit of good service!
Attentive inspection
Have you
noticed?
Input power (W)
2.5 W (Heating / Fan)
12.4 W (Cooling)
CAUTION (page 2, 3)
● Fan do not run when the unit is turned on.
● Abnormal noises or vibrations while the unit is running.
● Retarded or irregular rotations.
(Motors are component which requires maintenance.)
● Burnt odor.
● Corroded or damaged installation section.
Dimension (mm)
Width
Depth
492
812
492
1034
461
1130
If you hear strange sounds, if no air is blown out or if some other
trouble occurs, switch off the power and contact your dealer. Consult
with your dealer concerning the cost of inspection or repair work.
Stop
running.
Weight (kg)
Height
330
21
394
26
404
28
Turn off the unit. Then,
contact your dealer for
prevention of failure or
hazard. The dealer should
appraise the possible cost.
Eng-11