Water Right ECLIPSE WRO-35 Installation, Operation & Service Manual
Water Right ECLIPSE WRO-35 Installation, Operation & Service Manual

Water Right ECLIPSE WRO-35 Installation, Operation & Service Manual

R.o. drinking water system
Hide thumbs Also See for ECLIPSE WRO-35:

Advertisement

E C L I P S E
Reverse Osmosis
Drinking Water System
Installation, Operation & Service Manual
from Water-Right
WRO-35
R.O. Drinking
Water System
Sold and serviced
by authorized
Tested and Certified by NSF International against
Water-Right dealers.
NSF/ANSI Standard 58 for the reduction of the claims
specified on the Performance Data Sheet.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECLIPSE WRO-35 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Water Right ECLIPSE WRO-35

  • Page 1 E C L I P S E Reverse Osmosis Drinking Water System Installation, Operation & Service Manual from Water-Right WRO-35 R.O. Drinking Water System Sold and serviced by authorized Tested and Certified by NSF International against Water-Right dealers. NSF/ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Page SECTION I. INTRODUCTION ...................3 SECTION II. SPECIFICATIONS ................4 SECTION III. PREPARATION ..................5 A. Major System Components .............5 B. Tools Recommended for Installation ..........7 C. Site Selection For Major System Components .......7 SECTION IV. INSTALLATION STEPS ................8 A.
  • Page 3: Section I

    SECTION I. INTRODUCTION meters per gram of carbon) gives the carbon Your new Reverse Osmosis (R.O.) Drinking Water very good adsorptive sites for substances that System uses a combination of filtration technologies contribute to tastes and odors. to reduce unwanted contaminants in a water supply. IN–LINE ACTIVATED CARBON POST FILTER–...
  • Page 4: Specifications

    SECTION II. SPECIFICATIONS TABLE A – QUALIFIED SYSTEM PERFORMANCE Because the performance of an R.O. Membrane is highly dependent upon pressure, temperature and TDS, the following should be used for comparison purposes only. U.S. Metric Membrane Production 41-53 gpd 155–201 lpd Membrane TDS Reduction 96% minimum 96% minimum...
  • Page 5: Preparation

    SECTION III. PREPARATION A. Major System Components • A Sediment/Carbon Module, shrink wrapped. The following components comprise the R.O. Drinking Water System. (Refer to Fig. 1, below • An Activated Carbon Module, shrink wrapped. for general system layout.) • An In–Line Activated Carbon Post Filter, •...
  • Page 6 OPTIONAL WRO-35 BASEMENT INSTALLATION DIAGRAM Close-up of Manifold Dispensing Faucet water qualitY mOnitOr Faucet Base See Page 11 nOte: FOr reFrigeratOr water Dispenser Or prODuct ice maKer hOOKup, tee (3/8” Blue) intO 3/8" Blue tuBing tO Dispensing Faucet. water qualitY mOnitOr caBle hOlDing tanK shutOFF ValVe...
  • Page 7: Tools Recommended For Installation

    B. Tools Recommended for Installation 1. General Dimensions– The exact dimensions of the Eclipse RO unit are 14"H x 11.75"W x 4.5" The following tools will cover most of the deep. The storage tank measures 13.75" tall with installation sites encountered: a 9" diameter. It is recommended to choose a site "...
  • Page 8: Installation Steps

    SECTION IV. INSTALLATION STEPS 2c. Drilling a counter top: All plumbing should be done in accordance with NOTE: The counter top must be less than state and local plumbing codes. 1¼" thick. Treat ceramic tile as porcelain until NOTE: Some codes may require installation by a the tile is penetrated, then use the carbide licensed plumber;...
  • Page 9 5. Place the Toggles of the Monitor Housing Assembly through the mounting hole on the sink or counter top. Drop the handle of the Wrench through the Monitor Housing opening. This will separate and orient the Toggle Wings. Position the Monitor Housing so that 7.
  • Page 10: Feed Water Saddle Valve Installation

    FEED WATER SADDLE VALVE 2b. To install on (hard) steel or brass tubing supply line. •The supply line should now be drained. Use Cold Water Line a battery powered or properly grounded drill Saddle to avoid shock hazard. Reversible Back Plate •Drill a "...
  • Page 11: Manifold Assembly Installation

    2. Use a battery powered or properly grounded drill. Using the Clamp port as a drill guide, drill a " hole through the wall of the drain pipe. Do NOT penetrate the opposite side of the pipe. 3. Locate the "...
  • Page 12: Position The Drinking Water Holding Tank And Make The Final Hose Connections

    7. Remove the wrapping from the •Remove the plug labeled "Membrane" from the underside of the manifold. Trim In–Line Activated Carbon Post Filter. Slice " Blue Polytube where it would be top of membrane bag, exposing the white convenient to install and change the In–Line plastic seal.
  • Page 13: Operation And Maintenance

    SECTION V. OPERATION & MAINTENANCE The recommended interval for changing the A. Normal Operation modules (not the R.O. Membrane) is every 6 to 12 months. Typical T.F.C. Membrane life 1. It is normal for the Total Dissolved Solids expectancy is three years. Local conditions may (TDS) of the water to be higher than normal dictate more frequent changes.
  • Page 14: Changing The In-Line Activated Carbon Post Filter

    IN–LINE ACTIVATED CARBON POST FILTER ASSEMBLY Dispensing Faucet 3/8" Blue 3/8" Blue In-Line Activated Carbon Post Filter Figure 5 C. Changing the In–Line Activated Carbon Post Filter 1. Close the Feed Water Saddle Valve by turning fully clockwise. 2. Close the Holding Tank Valve and then open the Dispensing Faucet to release the pressure.
  • Page 15 NOTES:...
  • Page 16: Trouble Shooting Guide

    SECTION VI. TROUBLE SHOOTING GUIDE Problem Possible Cause Solution Low quantity of Product Water  Feed Water Saddle Valve is plugged or Open Valve or unclog. from Holding Tank closed. Clogged Sediment Module or Activated Replace Modules. Carbon Module. Low water pressure. Feed Water pressure must be above 40 psig.
  • Page 17 Problem Possible Cause Solution High Total Dissolved Solids (TDS)  The Product Water and Drain Water Correct plumbing. in the Product Water lines are reversed. (continued) No drain flow, Drain Restrictor is Clear or replace Drain Restrictor. clogged. No drain flow, the drain orifice in Clear or replace Dispensing Faucet. the Dispensing Faucet is plugged.
  • Page 18: Exploded View And Parts List

    EXPLODED VIEW & PARTS LIST 21..Nitrate/Nitrite Test Kit MADE IN USA...
  • Page 19 DRAWING NO. PART NO. DESCRIPTION 1 ....S2009 ......Self Tapping Screw 2 ....S2005 ......ASO Cap 3 ....S2013 ......ASO Cap O–Ring 4 ....S2011 ......ASO Diaphragm – Large 5 ....S2007 ......ASO Piston 6 ....S2006 ......ASO Piston Ring 7 ....
  • Page 20 eClIPSe™ R.o. DRInKInG WateR SYSteM FiVe/One Year limiteD warrantY What Does This Warranty Cover? This warranty covers any defects in materials and workmanship of the Eclipse R.O. Drinking Water System when installed and operated within recommended parameters, with the exceptions stated below. How Long Does The Coverage Last? Water-Right will warrant its Eclipse R.O.