BIS ULTIMA-1 506128-23 Installation And Operation Instructions Manual

BIS ULTIMA-1 506128-23 Installation And Operation Instructions Manual

Epa wood-burning fireplaces

Advertisement

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
An French manual is available upon request. Order P/N 506128-24.
Ce manuel est disponible en francais, simplement en faire la demande. Numéro
de la pièce 506128-24.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fitted with
an adjustable safety gate or barrier screen.
WARNING
Listed to standards:
ULC-S610 & UL-127
Report No. 3011202
EPA Cert. No. 537
PIBISULTIMA-A REV. 13 05/2013
INSTALLATION AND

OPERATION INSTRUCTIONS

BIS
®
EPA Wood-Burning Fireplaces
P/N 506128-23 REV. N 05/2013
MODEL
BIS Ultima-1
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
IHP wood-burning fireplaces are designed for use as a supplemental
heater. They are not intended for continuous use as a primary heat
source.
Fireplace, also for use in mobile or
manufactured homes with solid fuel only.
• The fireplace cannot be operated without a door
or firescreen. Consult your dealer to select the
correct door or firescreen.
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
ULTIMA-1
WARNING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULTIMA-1 506128-23 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BIS ULTIMA-1 506128-23

  • Page 1: Operation Instructions

    ® EPA Wood-Burning Fireplaces P/N 506128-23 REV. N 05/2013 MODEL BIS Ultima-1 This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
  • Page 2: Safety Rules And Specifications For Mobile Or Manufactured Home Installation

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Use care when selecting window Always ensure that the air inlet to RULES BEFORE YOUR FIRST FIRE. treatments for windows located the fireplace is free from debris near the fireplace. Avoid using and any other obstructions that combustible flowing window can block the entrance of air.
  • Page 3: Table Of Contents

    Gasket Replacement ......Page 8 Fireplace Installation ......Page 8 Not tested under EPA certification. If in- • The BIS Ultima-1 fireplace is not intended Locating The BIS Ultima-1 Fireplace .Page 8 stalled, this appliance no longer qualifies for use with a gas log set. Do not use a Framing, Facing And Mantel ....Page 9...
  • Page 4: Operating The Fireplace

    Primary Air and Air Boost Controls the first few fires of this appliance there may There is no flue damper in the BIS Ultima-1 be some odor and smoke due to the curing of USE SOLID NATURAL WOOD FUEL ONLY. The fireplace.
  • Page 5: Refueling For Best Performance

    Your This is the recommended mode of operating dealer can help you determine if you have The BIS Ultima-1 fireplace will operate best if the BIS Ultima-1 fireplace and should be the properly seasoned wood for burning.
  • Page 6: Chimney Maintenance

    MAINTAINING YOUR FIREPLACE Top Baffle Removal Prior to Cleaning The Dealing With a Chimney Fire Chimney Regular chimney maintenance and inspection Creosote - Formation and Need for Removal Before starting to clean your chimney, we When wood is burned slowly, it produces tar can prevent chimney fires.
  • Page 7: Refractory Replacement

    WARNING If the fit is still not perfect, you can adjust the door using the hinge screws. • Use only a IHP glass doors, specifically designed for the BIS Ultima-1 DOOR ADJUSTMENT fireplace. The door may need to be adjusted to be com- •...
  • Page 8: Glass Care - Replacement

    OR BROKEN GLASS. The BIS Ultima-1 fireplace may be installed Glass Cleaning directly on the floor or on a raised base (for The BIS Ultima-1 fireplace is designed to keep Gasket Length* Dimensions Part No.
  • Page 9: Framing, Facing And Mantel

    D. WARNING: The fireplace must not be in contact with any insulation or loose fill- ing material. Cover the insulation with Drywall panels around the fireplace. Hearth Extension Requirements The BIS Ultima-1 fireplace may be installed ® 12” Max. directly on a combustible floor. The supplied...
  • Page 10: Fireplace And Framing Dimensions

    Corner Installation Back Wall of Chase/Enclosure Combustion OUTSIDE CHASE Including Finising Materials if any Air Kit 19-3/32” 20-1/2” Rough Framing Face (Unfinished Shown) * Zero Clearance From Back Spacer to Wall FRAMING DIMENSIONS 36-3/8” 924 mm Combustible materials can NOT be used in the space directly above the fireplace.
  • Page 11: Insulated Chase Construction

    Insulate Joists Same As Ceiling Insulated Chase Construction Storm Collar Roof Support Flashing Draft Stops Attic Radiation Shield Floor Ceiling NOTE: It is recommended that the chase Firestop walls and floor be insulated in the same Wall manner, using the same insulation, as CTDT the rest of the building, below the attic.
  • Page 12: Hot Air Ducting Installation

    See Figures 14 and 15 45” Min. * The height of the louver must be measured (1143mm) from the base of the BIS Ultima-1 fireplace to the middle point of the louver. To extend the double outlet system forward of Non-Combustible...
  • Page 13: Central Forced Air Kit Installation

    1. Remove the plates closing up the 8” dia. G) At that point, the flexible pipe can be attached the sides of the BIS Ultima-1 fireplace allow holes on top of the fireplace. Then, cut to any air distribution grill. It is possible to the connection of insulated flexible pipe which the insulation in order to obtain two 8”...
  • Page 14: Outside Air Kit

    OUTSIDE AIR KIT - REqUIRED OUTSIDE CONNECTION During operation, the fireplace requires fresh air for combustion and draws air out of the house. It may starve other fuel burning appliances Aluminum Tape such as gas or oil furnaces. As well, exhaust blowers may compete for Outside air, causing negative pressure in the house, resulting in smoke entering Plastic Cover...
  • Page 15: Chimney System

    AC chimney enclosed in an insulated chase. 9. Cut and frame square holes in all floors, ceilings, and roof that the 2. The fireplace model BIS Ultima-1 may be installed only with Security ®...
  • Page 16: Chimney Installation Instructions

    CHIMNEY INSTALLATION INSTRUC- Attic Radiation Shield TIONS Attic Radiation ASHT / S2100 Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, floor Solid Packed Pipe * Flashing and roof where the chimney will pass (see Figure 22). Use a plumb-bob to line up the center of the holes.
  • Page 17: Offset Chimney Installation

    After reaching the location requiring the AC * elbow, proceed as follows: Air Cooled Chimney Chimney ASHT / HT6103+ / S2100+ / HT6000+ Chim- Collar neys Spacer (built into flashing) 1. Install the first elbow; turn it in the required direction.
  • Page 18 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 19: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Support ACRS NOTE: 45º angle for Canada only ( RSMI45 Straps In cold climate locations (climates where temperatures will fall below 32°...
  • Page 20: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support 18” (460 mm) 18” (460 mm) When installing a support, slightly lift the chimney system so the weight will lie on the support, not on the fireplace to reduce expansion noises. This support has three possible uses: 1.
  • Page 21: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: 1. Position the fireplace in its location. Temporarily install the ASHT WARNING: Before starting the installation, the masonry chimney must elbow on the top of the fireplace and, using a level, mark with an oval be inspected by a qualified chimney sweep.
  • Page 22: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Fireplace Kits Description Cat./Part No. Description Cat./Part No. Blower (heat activated on/off pre-wired), UZY5 UZY5 Door Kit (Required - Order Separately) Blower motor speed control (wall mount), VRUW VRUW Victorian Arch Shape Doors, Black BUVBK Rigid firescreen BUCEBWZN Contemporary Arch Shape Door, Black...
  • Page 23: Replacement Parts

    SPECIFICATIONS REPLACEMENT PARTS LIST Ultima-1 Replacement Parts ® Cat. No. Model Description Cat./Part No. BISULTIMA-1 BIS Ultima-1 Baffle refractory (2 pieces) PR-ISO2205 Back refractory PR-SR2203 Product Reference Information Right side refractory PR-SR2204D Weight 385 lbs Left side refractory PR-SR2204G Height 36”...
  • Page 24: Chimney Components Lists

    2125 Monterey, Laval, quebec 1-800-361-4909 (USA) Canada, H7L 3T6 1-800-667-3387 (Canada) www.securitychimneys.com Fireplace Model BIS® Ultima-1 - Approved Venting Components Secure Temp ASHT 1” High Temp. Insulated Stainless Steel Chimney ® manufactured by Security Chimneys International™ only. 6” I.D and 8” O.D., Double-Wall Stainl. Steel, Listed to CAN/UCL-S604 and UL-103HT Description Part/Cat.
  • Page 25 SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 ™ LL Chimney Lining System Tubinox 2125 Monterey, Laval, quebec 1-800-361-4909 (USA) Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6”...
  • Page 26: Product Reference Information

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your fireplace is covered by a limited warranty. Please read the warranty When ordering repair parts, always give the following information: to be familiar with its coverage.

Table of Contents