2nd & following judgment (every 10 minutes after 1st judgment)
If indoor intake temp – Remote control temp
setting ≥ +3
If -2 ≤ indoor intake temp. – Remote control
Temp. setting < +3
If indoor intake temp. – Remote control temp.
setting < -2
Intake temp.- setting temp.
Note:
• When auto judgment has been made to operate in Cool mode, the unit will enter different states according to
outdoor temperature conditions:-
Outdoor Temp. Condition
If outdoor temperature≥ -12℃
If outdoor temperature <-12℃
• During sampling and making judgment, POWER LED will blink.
• When judgment has been made, POWER LED will stop blinking and ON.
During AUTO mode operation, horizontal louver direction and FAN speed can be selected by remote control

11.2 Indoor Fan Motor Operation

A . Basic Rotation Speed
i.
Manual Fan speed
Fan motor's number of rotation is determined according to remote control setting.
Model
CS-RE9PKE-3
CS-RE12PKE-3
CS-RE15PKE-3
ii.
Auto Fan Speed (Cooling, Soft Dry Mode)
According to room temperature and setting temperature, indoor fan speed is determined automatically.
The indoor fan will operate according to pattern below.
Fan speed
A
Higher
Medium
Lower
B.
Feedback control
• Immediately after the fan motor started, feedback control is performed once every 0.5second.
• During fan motor on, if fan motor feedback 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error
counter increases, fan motor then stops and restarts. If the fan motor counter becomes 7 times, then H19 - fan motor
JUDGE CONDITION
HEAT
-6 -5 -4 -3
Air Conditioner Status
Cooling operation
Compressor OFF and standby.
Remote control
O
Tab
Hi
COOLING(rpm)
1150
HEATING(rpm)
1010
COOLING(rpm)
1150
HEATING(rpm)
1150
COOLING(rpm)
1250
HEATING(rpm)
1300
b
c
d
REFERANCE MODE
Cool mode if previously
Heat mode
Dry mode if previously is Dry mode
Maintain current mode
MAINTAIN
CURRENT MODE
-2 -1 0
O
O
Me+
Me
1030
920
890
830
1060
970
1010
950
1130
1020
1140
1060
e
f
g
27
is Cool /
Heat mode
COOL/DRY
1
2
3
4
5
6
O
O
Me-
Lo
810
700
770
710
880
790
890
830
910
800
980
900
h
a
b
QUIET
QLo
600
650
620
680
730
740