Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
HUMIDITY SENSOR
Refer to page 4-4 for the procedure for servic-
ing the humidity sensor.
1.
Unplug the microwave oven or disconnect
the power.
2.
Disconnect the 3-wire connector from the
control board.
3.
Set the ohmmeter to the R x 1K scale.
4.
Touch the meter leads to the indicated
wire terminals of the 3-wire connector.
The meter should indicate as follows:
Black to white = approximately 2800 Ω
@ 77˚F/25˚C.
White to red = approximately 2800 Ω
@ 77˚F/25˚C.
WARNING
Electrical Shock Hazard
CAVITY THERMOSTATS 1, 2, & 3
Refer to pages 4-4 and 4-8 for the procedures
for servicing the cavity thermostats.
1.
Unplug the microwave oven or disconnect
the power.
2.
Disconnect the wires from the terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter leads to the termi-
nals. The meter should indicate a closed
circuit (0 Ω).
NOTE: Thermostat 1 opens @ 329°F / 165°C.
Thermostats 2 and 3 open @ 257°F / 125°C. If
the thermostat is defective, the ohmmeter will
indicate an infinite circuit.
5-4