Specifications - Orion Network Pro 1000 User Manual

Network pro series tower and rack-mount convertible ups
Table of Contents

Advertisement

9

SPECIFICATIONS

9.1 120V
Model number
750/1000VA
Power Rating, VA/W
750VA/750W
1000VA/900W
Dimensions, W x D x H, in
Unit
3.5"(2U) H x
18"W x
17"D
Weight, lbs
Unit
45
Input AC Parameters
Surge Protection
Voltage Range
Without
Battery Operation
Frequency Range
Input Power Cord
10ft(3m)
attached,
w/ NEMA 5-15P
Output Receptacles
(8) NEMA 5-15R
Voltage (Normal
mode)
Voltage (Battery
Mode)
Transfer Time
Waveform
Frequency
(Normal Mode)
Frequency
(Battery Mode)
Overload Warning
>100% - 109%
Normal Mode
>110% - 120%
>120%
>100% - 119%
Battery Mode
>120% - 130%
>130%
Battery Parameters
Type
1500VA
2200VA
1500VA/1350W
1920VA/1920W
3.5"(2U) H x
3.5"(2U) H x
18"W x
18"W x
17"D
26"D
48
77
570J
83~159, configurable
45~65Hz, (±0.5Hz)
10ft(3m)
10ft(3m)
10ft(3m) attached,
attached,
attached,
w/ NEMA L5-30P
w/ NEMA 5-15P
w/ NEMA 5-20P
(8) NEMA 5-15R
(6) NEMA 5-15R
(6) NEMA 5-15R
(2) NEMA 5-20R
(2) NEMA 5-20R
(1) NEMA L5-30R
110 / 120 / 127 VAC (configurable) ±10%
110 / 120 / 127 VAC (configurable);
±5% before low battery warning
4-6 ms typical
Sinewave
45~65Hz, (±0.5Hz)
50/60Hz, (±0.5Hz), auto sensing
Continuous Overload Alarm and power to the load
Shutdown after 10 minutes
Shutdown UPS immediately
Continuous Overload Alarm till end of battery discharged
Shutdown after 10 seconds
Shutdown UPS immediately
Valve-regulated, nonspillable, lead acid
32
Backup Time *
3000VA
Full Load
Half Load
3000VA/2700W
Recharge Time
Environmental
3.5"(2U) H x
Operating
Temperature
18"W x
Storage Temperature
26"D
Relative Humidity
85
Operating Altitude
Audible Noise
Agency
Safety
Surge
Susceptibility
Electrical Fast
Transient
Emissions
Conducted Immunity
Harmonics
Network surge
Transportation
*
Runtimes reflect .7 power factor and are approximate. Run times may vary depending on
battery age, temperature, etc.
1000VA
1500VA
7m
5m
19m
16m
5 hours to 90% of rated capacity, after full discharge into resistive load
+32°F to + 104°F (0°C to + 40°C)
+5°F to + 104°F (-15°C to + 40°C)
0% to 95%, non-condensing
Up to 10,000 ft. (3000m) at 95°F (35°C) without derating
<40 dBA, internal fan(s) Off
<45 dBA, internal fan(s) On
UL 1778, c-UL Listed
ANSI C62.41 CatA Lev3 (surges)
IEC61000-4-5
ESD
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
FCC Part 15, Class A
EN61000-4-6
EN61000-3-2
UL 497 B
ISTA Procedure 1A Certification
33
2200VA
3000VA
5m
5m
16m
16m
<40 dBA, internal fan(s) Off
<45 dBA, internal fan(s) On