Probe Cover And Probe Switch; Temperature Sensor - Wolf Wall Oven-2 Series Technical & Service Manual

Wall oven series
Table of Contents

Advertisement

W W a a l l l l O O v v e e n n S S e e r r i i e e s s
W W a a l l l l O O v v e e n n S S e e r r i i e e s s
Component Access & Removal
Probe Cover and Probe Switch Removal
To remove the probe cover, first you will need to raise
the probe cover up. Now, using a wrench, loosen and
remove the nut. Now, the cover can be removed.
(See Figure 4-27).
NOTE: To remove the probe switch the unit will need
to be pulled from its installation approximately 8 inches.
Next, extract the screw and remove the access panel
for the probe switch. Now, pull the switch from the
oven cavity and disconnect the wires from the switch
terminals. (See Figure 4-28).
Figure 4-27. Probe Cover Removal.
Temperature Sensor Removal
Extract the two screws which secure the sensor to the
oven cavity. (See Figure 4-29). Next, carefully pull the
sensor with wire leads straight out from the oven cavity,
until the molex connector is inside the oven cavity.
(See Figure 4-30). Now, unplug the molex connector
and remove the temperature sensor.
NOTE: When the molex connector is disconnected,
make sure the male end of the connector doesn't fall
back into the hole. If it does, the unit may have to be
pulled out from its installation in order to reconnect the
molex connectors for the sensor.
Figure 4-28. Probe Switch Removal.
Figure 4-29. Temperature Sensor Removal.
4-10

Advertisement

Table of Contents
loading

Table of Contents