9-7. Insulation Tests

On completion of disassembly and repair, measure the insulation resistance and conduct dielectric strength test.

9-8. No-Load Current Values

After 30 minutes of no-load operation, current values should be as follows:
110 V
115 V
Less than 1.8 A
120 V
127 V
220 V ......... Less than 1.0 A
230 V ......... Less than 0.9 A
240 V ......... Less than 0.9 A
--- 14 ---