Section 6 — Electrical Data
Air-cooled 7 kW, 12 kW and 15 kW Generators
Wiring Diagram – 7 kW – Drawing No. 0D9013-C
DIAGRAM KEY
BA - BRUSH ASSEMBLY
BCR - BATTERY CHARGE RELAY
CB1 - MAIN OUTPUT BREAKER
CB2 - CIRCUIT BREAKER, ALTERNATOR EXCITATION
D - DIODE
DSW - PCB MOUNTED DIP SWITCH
FS - FUEL SOLENOID
F1 - FUSE 15 AMP
F2 - FUSE 5 AMP
GRD - CONTROL PANEL GROUND
HTO - HIGH OIL TEMPERATURE SWITCH
IC - INLINE CONNECTOR
ICT - INTERCONNECTION TERMINALS
IM - IGNITION MODULE
LOP - LOW OIL PRESSURE SWITCH
SC - STARTER CONTACTOR
SP - SPARK PLUG
SW1 - AUTO / OFF / MANUAL SWITCH
SW2 - SET EXERCISE SWITCH
SM - STARTER MOTOR
TB - INSULATED TERMINAL BLOCK
TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.)
SP
IM
85
HTO
LOP
BLACK
-
+
12V
BATTERY
CUSTOMER SUPPLIED
28
ENGINE WIRING
IC
D
IC
86
IC
13
RED
SM
14
0
FS
0
14
14
6
0
18
5
85
4
86
3
2
13
0
1
C1
56
56
86
0
56
85
SC
PRINTED CIRCUIT BOARD
ON
16
1 - 20 Vac Sense Transformer
2 - Remote Not Auto
3 - 50 Hz Operation
4 - SPARE
L.E.D - ALARM INDICATORS
3
BATTERY
1
CHARGER
(UTILITY)
2
1
225B
224B
13A
0
14
0
14
13
18
351
56
1 2
3
4
5
J2
4
J1
56
CONTROL
14
DSW
13A
0
225B
224B
14
0
0
13
4
23
194
18
66A
239
15A
17
15
0
225
224