External digital input 1
1. Alarm Input
When "ON" is selected: external alarm will be detected.
The following functions will be enabled when the option "Alarm Input" is
selected.
B/W mode: The camera is switched to monochrome mode when a trigger
signal is received.
2. Input Type
Normally Open (NO): open if nothing occurs but closed in case of an alarm.
Normally Closed (NC): closed if nothing occurs but open in case of an alarm.
3. Text Enable
When "ON" is selected, an alarm message will be displayed on the screen.
4. Text
Enter a text for the alarm message.
Max. 22 characters can be entered.
5. Audio Output
When "ON" is selected, an audio alarm message will be sent to an external
speaker.
A speaker with integrated amplifier inside has to be connected to the AUDIO out
jack.
6. Event
Select an event.
Pre-recorded voice files with the extension .wav that have been uploaded to
the SD memory card can be selected as alarm messages. Up to 10 audio
sources can be selected.
7. Actions
Default is OFF, preset can be selected 1~16.