Specifications

Water Heater
Capacity - Litres
Boost Capacity - Litres
Booster element rating - kW
T&PR valve Rating - kPa
Maximum inlet pressure - kPa
Water Connections
Anode
Compressor t/stat setting (fixed) - ºC
Booster thermostat setting (trade adjustable) - ºC
Booster ECO setting - ºC
*Delivered water temperature 65-75ºC
Refrigeration System
Parameter
Superheat setting (Factory)
Compressor ECO setting
Refrigerant charge
Bypass solenoid coil resistance
Capacitor
Fan motor winding resistance
De-ice thermostat
Evaporator thermostat
Compressor winding resistance

Preventative Maintenance

It is suggested for peak performance that the water heater be serviced annually.
1. Check for discharge from the T&PR valve. When the elements are operating a small
discharge of water may be evident. Operate the valve-easing lever to ensure the valve
opens and resets properly. Always open and close the valve gently. The T& PR valve
should be replaced at 5 yearly intervals.
2. Check for leaks at all cylinder fittings.
3. Check for signs of excessive corrosion on the water heater jacket.
4. Isolate power to the water heater and check all electrical connections for signs of
overheating due to poor connection.
5. Conduct an 'Electrical insulation test' on the water heater. (Refer to page 30)
6. Check evaporator fins and fan blade for build up of dust or debris.
7. Check for sludge build up and if necessary drain and flush tank.
TM017 Rheem Air Sourced Heat Pump Service Instructions REV: C
Date of Issue: 5/11/05
This document is stored and maintained electronically by
With ECV
Without ECV
Inlet / Outlet
T&PR
Quantity
Length
R22
R409A
2 kilo-ohms @ 20ºC
Closed
Open
Run winding - Red & Blue: 3.33 ohms
Start winding - Red & Black: 6.01 ohms at 20ºC
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled".
Model
55027500
275
Not fitted
1000
680
800
RP¾/20
RP½/15
1153
49ºC*
Not fitted
N/A
55027500
+3ºC at 10ºC Evaporator temp.
105ºC, manual reset
1350 grams
1250 grams
25 microfarads 370/450 VAC 50/60HZ
47.2 ohms at 20ºC
–3.5ºC
3ºC +/- 1.5ºC
Not fitted
3
55127507
275
0
130
2.4 or 3.6
1000
680
800
RP¾/20
RP½/15
2
1153
55ºC*
60ºC
85ºC
55127507
Not fitted
Not fitted
Closed 7ºC +/- 1.5ºC
Open
–3.5ºC evap temp
2