Component Tests 5 & 6
Ensure power is isolated before conducting this test
Warning – "Live" equipment Personal Protective Equipment should be worn when
TM017 Rheem Air Sourced Heat Pump Service Instructions REV: C
Date of Issue: 5/11/05
This document is stored and maintained electronically by
Test 5
Test 6
conducting this test.
17
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled".
Disconnect the wiring to the
capacitor and using a multimeter
set on the capacitance (uf) scale
measure across the capacitor
terminals.
Normal capacitance is 25uF
Using a multimeter set on the AC
volts scale, measure between
terminal 5 and neutral on the
terminal strip.
Normal voltage is 240 volts