Insulation Tests; Deflection Of Saw Blade; Cleaning The Case - Hitachi C 6MFA Technical Data And Service Manual

Circular saws
Hide thumbs Also See for C 6MFA:
Table of Contents

Advertisement

(8) Tightening torque values for selected fasteners
Bolt (W/Washer) M7 x 17.5 [14] ............................................................... 9.8
Seal Lock Screw (W/Sp. Washers) M6 x 14 [65] ..................................... 2.9
Seal Lock Flat Hd. Screw M5 x 12 [4] ...................................................... 3.4
Seal Lock Flat Hd. Screw M3 x 12 [10] .................................................... 1.8
Machine Screw (W/Washers) M4 x 10 [16] .............................................. 1.8
Machine Screws (W/Washers) M5 x 45 [17] ............................................ 3.4
Machine Screw M5 x 12 [37] .................................................................... 3.4
Hex. Hd. Tapping Screws D5 x 55 [47] .................................................... 2.9
Tapping Screws (W/Flange) D4 [18] [46] ................................................. 2.0
Hex. Socket Set Screws M5 x 6 [34] ........................................................ 2.0
Brush Caps [42] ....................................................................................... 0.7
Hex. Socket Set Screws M5 x 8 [39] ........................................................ 0.7
Flat Hd. Screw M6 x 20 [52] ..................................................................... 0.7
Seal lock hex. socket hd. screw M6 for Sleeve [58] ................................. 3.4
Set screws M3.5 x 7.5 for Switch (2P Pillar Type) W/Safety Lock [55] .... 0.3
Cap Nut M10 [33] ..................................................................................... 7.8 to 9.8 N

8-3. Insulation Tests

On completion of disassembly and repair, measure the insulation resistance and conduct dielectric strength test.
Insulation resistance: 7 M Ω or more with DC 500 V megohm tester
Dielectric strength: AC 4000 V/1 minute, with no abnormalities

8-4. Deflection of Saw Blade

Allowable deflection level of the saw blade shall be as follows.
C 6MFA, C 7MFA

8-5. Cleaning the Case

When the unit becomes soiled, clean it with a clean soft rag moistened with soapy water. Since chloric solvents,
gasoline and thinner tend to melt plastic material, their use for cleaning is absolutely avoided.
Model
Measuring point
Allowable level
150
0.3 mm max.
--- 11 ---
2.0 N
m 100
20 kgf
0.5 N
m 30
5 kgf
0.7 N
m 35
7 kgf
0.4 N
m 18
4 kgf
cm
0.4 N
m 18
4 kgf
cm
0.7 N
m 35
7 kgf
0.7 N
m 35
7 kgf
0.5 N
m 30
5 kgf
0.5 N
m 20
5 kgf
0.5 N
m 20
5 kgf
0.2 N
m 7.5
2.5 kgf
0.2 N
m 7.5
2.5 kgf
0.2 N
m 7.5
2.5 kgf
0.7 N
m 35
7 kgf
+ 0.07
+ 0.75
N
m
3
kgf
cm
-- 0.05
-- 0.5
m 80 to 100 kgf
cm
cm
cm
cm
cm
cm
cm
cm
cm
cm
cm
cm
cm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C 7mfa

Table of Contents