SECTION
5
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
MANUAL
ADVANCE
REGENERATION
CHECK
This check
verifies
proper
operation
of the valve
motor,
brine
tank fill, brine
draw,
regeneration
flow
rates,
and other
controller
functions.
Always
make
the initial
checks,
and
the manual
initiated
diag-
nostics.
Note:
If water
system
pressure
is low, an elevated
drain
hose may cause back pressure,
stopping
brine
draw.
Again
press
RECHARGE
to move
the softener
into backwash.
Look for a fast flow of water
from
the drain
hose.
Notes:
The faceplate
display
must
show a steady
time (not
flashing).
If an error
code shows,
first press
the SE-
LECT button
to enter
the diagnostic
display.
Press
the RECHARGE
button
hold
in
3
and
for
seconds.
RECHARGENOWbegins
to flashinthe
display
as the softener
enters
the fill cycle of re-
generation.
Remove
the brinewell
cover and, us-
ing a flashlight,
observe
fill water
entering
the
tank.
a. An obstructed
flow indicates
a plugged
top dis-
tributor,
backwash
flow plug,
or drain
hose.
Press RECHARGE
to move
softener
into
the
fast
rinse.
Again
look for a fast drain
flow. Allow
the
softener
to rinse
for a few minutes
to flush
out
any brine
that may remain
in the resin
tank from
the brining
cycle test.
To return
softener
to service,
press
RE-
the
CHARGE.
a. If water
does
not enter
the tank,
look for an ob-
structed
nozzle,
venturi,
fill flow plug,
brine tubing,
or brine
valve
riser pipe.
CYCLE FLOW RATES (GALLONS
PER MIN.)
FILL (flow to salt storage tank)
0.3 (1.1 liters)
BRINING
_
.15 (.57 liters)
BRINE RINSE
I
(flow
.1 (.38 liters)
to
MAX. BACKWASH
drain)
2.0 (7.6 liters)
MAX. FAST RINSE
2.0 (7.6 liters)
After
observing
fill, press
the RECHARGE
but-
ton
to move
the softener
into brining.
A slow
flow of water
to the drain
will begin.
Verify brine
draw
from
the brine
tank
by shining
a flashlight
into
the brinewell
and
observing
a noticeable
drop
in the liquid
level.
Note:
Be sure a salt bridge
is not preventing
water
with
salt contact.
a. If the softener
does not draw
brine...
...nozzle
and/or
venturi
dirty
or defective.
...nozzle
and venturi
not seated
properly
on gasket.
...restricted
drain
(check
drain
fitting
and hose).
...defective
nozzle
and venturi
seal.
...other
inner
valve
defect
(rotor
seal, rotor
& disc,
wave
washer,
etc.).
17
BRINE VALVE
, '
FLOAT SETTING
/_
float stop
floa,
FREEBOARD MEASUREMENT
Distance from top of resin tank, to top of resin bed.)
t
FREEBOARD
7"-11"
1
resin tank
5-4
Problems,