Climette CA1516KR Installation And Operating Instructions Manual

Advertisement

Installation and Operating

NOTE TO EQUIPMENT OWNER:
Thank you very much for purchasing a Climette Airconditioner. Please read this Owner's
Information Manual carefully before installing and using this appliance and keep this manual
for future reference.
For your convenience, please record the model and serial numbers of your new equipment
in the spaces provided. This information, along with the installation data and dealer contact
information, will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model # _____________________________________
Serial # ______________________________________
INSTALLATION INFORMATION
Date Installed ________________________________
Instructions
Fig. 1 --- Remote Control Unit
DEALERSHIP CONTACT INFORMATION
Company Name_______________________________
Address______________________________________
_____________________________________________
Phone Number _______________________________
Technician Name _____________________________
_____________________________________________
CA1516KR, CA1826KR, CA2326KR
Room Air Conditioner
Part Number 421 02 9120 00 - Printed 02/08

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CA1516KR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Climette CA1516KR

  • Page 1: Installation And Operating

    Instructions Fig. 1 --- Remote Control Unit NOTE TO EQUIPMENT OWNER: Thank you very much for purchasing a Climette Airconditioner. Please read this Owner’s Information Manual carefully before installing and using this appliance and keep this manual for future reference.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS ................. . . INTRODUCTION .
  • Page 3: Safety Considerations

    SAFETY CONSIDERATIONS suggestions which will result in enhanced installation, reliability, or operation. Recognize safety information. This is the safety- -alert symbol INTRODUCTION When you see this symbol on the unit and in instructions or Thank you for choosing this room air conditioner to cool your manuals, be alert to the potential for personal injury.
  • Page 4: Electrical Specifications

    ELECTRICAL SPECIFICATIONS WARNING 1. All wiring must comply with local and national electrical codes and must be installed by a licenced electrician. If you ELECTRICAL SHOCK HAZARD have any questions regarding the following instructions, Failure to follow this warning could result in personal contact a licenced electrician.
  • Page 5: Tips Before Installation

    TIPS BEFORE INSTALLATION CAUTION UNIT OPERATION HAZARD Failure to follow this caution may result in damage to unit components. To avoid installation/operating difficulties, read the A06531 instructions thoroughly. Fig. 3 --- Power Supply Cord Your Room Air Conditioner unit is designed to be highly efficient NOTE: Save the shipping carton and packing materials for future and save energy.
  • Page 6: Installation Instructions

    INSTALLATION INSTRUCTIONS Window Opening Requirements CAUTION MODEL SIZE 14K---23K Cabinet Size PERSONAL INJURY/UNIT OPERATION HAZARD 22.8”/15.7”/24.1” 26.5”/18.5”/26.9” (W/H/D) Failure to follow this caution may result in personal injury Window Opening 27” --- 41” 30” --- 44” and/or damage to unit components. Width It is recommended to have someone assist you during the Window Opening...
  • Page 7 NOTE: For 14K to 23K models, the bottom channel has been (TOP VIEW) factory- -installed, and their shapes may differ from the others, but V-slot their functions are similar. Step 4 —Assembly of the side shutters (curtains) to the cabinet. A.
  • Page 8 C. In very humid areas, the water removal may be excessive enough to overflow the unit or increase the noise of the air conditioner. If this occurs, you may wish to attach a drain hose (not included) to the drain plug allowing condensations to run off conveniently (see Fig.
  • Page 9: Storm Window Applications

    STORM WINDOW APPLICATIONS If the window is blocked by a storm window and the storm window cannot be removed, a mounting board (field provided) will need to be added to the window sash. The air conditioner needs to be pitched downward to the back in order for condensate to drain properly.
  • Page 10: Wall Installations

    WALL INSTALLATION To install the room air conditioner in the wall, perform the following procedure: 1. Remove air conditioner from shipping box. Do not install window installation parts. 2. Determine the location for air conditioner. Make sure there is adequate clearance on the inside and outside of the wall. Ensure that the power cord will reach the available socket without an extension cord.
  • Page 11: Masonry Construction

    11. Caulk joints in wood frame as required. If wall thickness is 7” or more, add aluminum flashing over bottom of frame opening to ensure no water can enter area between inner and outer wall. 12. Remove the chassis from the unit cabinet. CAUTION PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury.
  • Page 12: Operating Instructions

    OPERATING INSTRUCTIONS Electronic Control Panel Model Airc onditioner You can easily operate this air conditioner by pressing relevant button on the control panel as well as the remote control Button Tim er The air conditioner will be started when it is energized or will be stopped when it is in operation, if you press this button.
  • Page 13: Power Button

    Remote Control Power BUTTON The appliance will be started when it is energized or will be stopped when it is in operation, if you press this button. Power Timer Mode BUTTON Used to select the operation mode. Mode Power Saver BUTTONS Auto Used to set room temperature in Cooling...
  • Page 14: Care And Maintenance

    CARE AND MAINTENANCE CAUTION When servicing the air conditioner, be sure to turn the mode switch to the “OFF” position and disconnect the power cord from the UNIT DAMAGE HAZARD electrical outlet. Failure to follow this caution may result in unit damage CAUTION and/or improper operation.
  • Page 15: Warranty

    International Comfort Products, LLC Room Air Conditioner Limited Warranty Subject to the conditions and exclusions listed below International Comfort Products LLC (hereinafter referred to as “ ICP”) warrants this product against failures due to defects in materials and workmanship. TWO YEAR WARRANTY - ICP warrants to the initial purchaser of this product against failures due to defects in materials or workmanship under normal use and maintenance for a period of two years from the date of original purchase.