Closed System/Thermal Expansion; Temperature And Pressure Relief Valve; T&P Relief Valve And Pipe Insulation - Kenmore HydroSense 153.331592 Owner's Manual

Kenmore water heater user manual
Table of Contents

Advertisement

Closed
System/Thermal
Expansion
. All water heaters eventually leak
• Do notinstallwithout
adequate drainage,
As water is heated, it expands (thermal expansion). In a closed
system, the volume of water wilt grow. As the volume of water
grows, there wilt be a corresponding
increase in water pressure
due to thermal
expansion.
Thermal
expansion
can cause
premature tank failure (leakage). This type of failure is not covered
under the limited warranty. Thermal expansion
can also cause
intermittent
temperature-pressure
relief valve operation: water
discharged from the valve due to excessive pressure build up. The
temperature-pressure
relief valve is not intended for the constant
relief of thermal expansion. This condition is not covered under
the limited warranty.
A properly sized thermal expansion
tank should be installed
on all closed systems to control the harmful effects of thermal
expansion. Thermal expansion tanks are available from Sears
stores and through the Sears Service Centers.
Contact the
local
plumbing
inspector,
water
supplier
and/or
the Sears
Service Center for assistance
in controlling
these situations.
(For additional information, see the Troubleshooting
Guide later
in this manual.)
Temperature
and Pressure
Relief Valve
Explosion
Harzard
Temperature-pressure
relief
valve must comply with ANSI
Z21.22-CSA
4.4 and ASME
code.
• Properly sized temperature-
pressure
relief valve must be
installed in opening provided.
• Can result in overheating
and excessive
tank pressure.
• Can cause serious injury or
death.
\
TEMPERATURE
AND
PRESSURE
(T&P)
RELIEF
VALVE
(OPTIONAL
TOP T&P
RELIEF
VALVE
NOT
SHOWN)
DISCHARGE
PIPE
(DO
NOT
CAP OR PLUG)
DRAIN
LINE
3/4"
ID
i INIMuM
I"METALMINIMUM--=._
_
& 6" MAXIMUM
DRAIN
PAN --_-_
__
AIR GAP
DRAIN _
FIGURE 24.
For protection against excessive pressures and temperatures,
a temperature
and pressure relief valve must be installed in the
opening marked "T & P RELIEF VALVE." (See Figure 24). This
valve must be design certified by a nationally recognized testing
laboratory that maintains periodic inspection of the production
of listed equipment
or materials as meeting the requirements
for Relief Valves for Hot Water Supply Systems, ANSI Z21.22.
The function of the temperature
and pressure relief valve is to
discharge water in large quantities
in the event of excessive
temperature
or pressure developing
in the water heater. The
valve's relief pressure must not exceed the working pressure of
the water heater as stated on the rating plate.
IMPORTANT: Only a new temperature and pressure relief valve
should be used with your water heater. Do not use an old or
existing valve as it may be damaged
or not adequate for the
working pressure of the new water heater. Do not place any
valve between the relief valve and the tank.
The Temperature
& Pressure
Relief Valve:
Must not be in contact with any electrical part
Must be connected to an adequate discharge line
Must not be rated higher than the working pressure shown
on the rating plate of the water heater
The Discharge
Line:
Must not be smaller than the pipe size of the relief valve or
have any reducing coupling installed in the discharge line
Must not be capped, blocked, plugged or contain any valve
between the relief valve and the end of the discharge line
Must terminate
a maximum of six inches above a floor
drain or external to the building
Must be capable of withstanding 250°F (121°C)without distortion
Must be installed to allow complete
drainage of both the
valve and discharge line
T&P
Relief
Valve
and
Pipe
Insulation
1.
Locate the T&P Relief Valve on the water heater.
2.
Locate the slit running the length of the insulation.
3
Spread this slit open and slip it up under the T&P Relief
Valve. See Figure 25. Apply gentle pressure to the insulation
to ensure it is fully seated on the T&P Relief Valve.
Once
sealed
secure
the
insulation
with
a section
of tape.
IMPORTANT:
The insulation or tape should not block or
cover the T&P Relief Valve drain opening. Also the insulation
or tape should not block or hinder access to the T&P Relief
Valve manual relief lever.
4.
Next locate the hot water (outlet) & cold water (inlet) pipes to
the water heater.
5.
Select one of the sections of pipe insulation and locate the slit
that runs the length of the insulation.
6.
Spread the slit open at the base of the insulation and slip it
over the cold water (inlet) pipe. Apply gentle pressure along
the length of the insulation to ensure it is fully seated around
the cold water pipe. Also ensure that the base of insulation is
flush with the water heater. Once seated, secure the insulation
with a section of tape.
7.
Repeat steps 5 through 6 for the hot water (outlet) pipe.
T&P
RELIEF
VALVE
INSULATION
MANUAL
RELIEF
LEVER
©
DRAIN
LINE
FIGURE 25.
21