Removing The Old Water Heater - Kenmore HydroSense 153.331592 Owner's Manual

Kenmore water heater user manual
Table of Contents

Advertisement

Removing
the Old Water Heater
C)
Q
MANUALGAS
SHUT-OFFVALVE---.....
GROUND-----=
JOINT
UNION
CHECK WITH
LOCAL UTILITY
FOR MINIMUM HEIGHT
3" MINIMUM
,
DRIP LEG_
@
DISCHARGE
PIPE
(DO NOT CAP
OR PLUG)
//_
GAS CONTROL
VALVE/
THERMOSTAT
_)
DRAIN VALVE
6" MAXIMUM
_
T AIR GAP
SUITABLE "_"_f
DRAIN
FIGURE
2.
©
Turn "OFF" the gas supply to the
water heater.
If the main gas line shutoff valve
serving all gas appliances is used,
also shut "OFF" the gas at each
appliance. Leave all gas appliances
shut "OFF" until the water heater
installation
is completed.
See
Figures 2 and 3.
FIGURE
3.
®
®
Open a nearby
hot water
faucet
and
leave
it open
to allow
for
draining.
Allow
the hot water
to run until water
flowing
from
the faucet
is 100 ° F or less.
Connect a hose to the drain valve
and terminate
to an adequate
drain or outdoors.
(Make sure all
connections
are tight and that the
water flow is directed
away from
people.)
Open
the drain
valve
and allow the tank to drain.
(See
Figures 2 and 5.)
FIGURE
5.
Disconnect
the vent pipe from the draft hood where it connects
to the water heater.
In most installations
the vent pipe can
be lifted off after any screw
or other attached
devices
are
removed.
Dispose
of the draft hood.
The new water heater
has a draft hood which must be used for proper operation.
If you have copper piping to the water heater, the two copper
water
pipes can be cut with a hacksaw
approximately
four
inches away from where
they connect
to the water heater.
See Figure
6. This will avoid
cutting
off pipes too short.
Additional
cuts can be made later if necessary.
Disconnect
the
temperature-pressure
relief valve drain line. When the water
heater is drained,
disconnect
the hose from the drain valve.
Close the drain valve. The water heater
is now completely
disconnected
and ready to be removed.
FIGURE
6.
®
Turn "OFF" the water supply
to
the water
heater
at the water
shut off valve
or water
meter.
Some installations
require that
the water
be turned
off to the
entire
house.
See
Figures
2
and 4.
FIGURE
4.
If you have galvanized
pipes to the water
heater,
loosen
the two galvanized
pipes with a pipe wrench
at the union in
each line. Also disconnect
the piping remaining
to the water
heater. See Figure 7. These
pieces should
be saved since
they may be needed when reconnecting
the new water heater.
Disconnect
the temperature-pressure
relief valve drain line.
®
Check again to make sure the gas supply is "OFF" to the water
heater. Then disconnect
the gas supply connection
from the
gas control valve.
Ir I,7:1
[€']:1;I
• Burn hazard
• Hotwater discharge.
• Keep hands clear of drain
valve discharge.
When the water heater is drained,
disconnect
the hose from
the drain valve.
Close the drain
valve.
The water
heater
is now completely
disconnected
and ready to be removed.
Mineral
buildup
or sediment
may have accumulated
in the
old water heater.
This causes
the water heater to be much
heavier
than normal
and this residue,
if spilled
out, could
cause staining.
FIGURE
7.
11