Troubleshooting Chart - Amana GDH8 Installation Instructions Manual

Gas furnace
Hide thumbs Also See for GDH8:
Table of Contents

Advertisement

T
ROUBLESHOOTING
Associated
Symptoms of
Abnormal Operation
LED Code
• Furnace fails to operate.
• Integrated control module
diagnostic LED provides
no signal.
• Furnace fails to operate.
• Furnace fails to operate.
• Integrated control module
diagnostic LED is
flashing ONE (1) flash.
• Furnace fails to operate.
• Integrated control module
diagnostic LED is
flashing TWO (2)
2 FLASHES
flashes.
• Induced draft blower
runs continuously with
no further furnace
operation.
• Integrated control module
3 FLASHES
diagnostic LED is
flashing THREE (3)
flashes.
1
Integrated control module will automatically attempt to reset from lockout after one hour.
2
LED Flash code will cease if power to the control module is interrupted through the disconnect or door switch.
C
HART
Fault
2
Description(s)
NONE
• No 115 volt power to
furnace, or no 24
volt power to
integrated control
module.
• Blown fuse or circuit
breaker.
• Integrated control
module has an
internal fault.
• Furnace lockout due
to an excessive
1
number of ignition
1
attempts. (3 total)
1 FLASH
• Auxiliary Limit Open
• Pressure switch
circuit is closed.
2
• Induced draft blower
is not operating.
• Pressure switch
circuit not closed.
3
• Induced draft blower
is operating.
• If installed, manual
reset limit switch is
open on Masonry
Vent Kit (MVK).
Possible
Causes
• Assure 115 and 24 volt
• Manual disconnect switch
OFF, door switch open, or
24 volt wires improperly
connected or loose.
• Check integrated control
• Blown fuse or circuit
breaker.
• Check for possible
• Integrated control module
• Replace bad integrated
has an internal fault.
• Failure to establish flame.
Cause may be no gas to
burners, bad igniter or
igniter alignment, improper
orifices, or coated/
oxidized or improperly
connected flame sensor.
• Loss of flame after
establishment. Cause may
be interrupted gas supply,
lazy burner flames
(improper gas pressure or
restriction in flue or
improper induced draft
blower performance.
• Insufficient conditioned air
over the heat exchanger.
Blocked filters, restrictive
ductwork, improper
circulator blower speed,
or failed circulator blower.
• Induced draft blower
pressure switch contacts
sticking.
• Shorts in pressure switch
circuit.
• Inspect pressure switch
• Pressure switch hose
blocked, pinched or
connected improperly.
• Inspect flue for blockage,
• Blocked flue or weak
induced draft blower.
• Incorrect pressure switch
• Correct pressure switch
setpoint or malfunctioning
switch contacts.
• Tighten or correct wiring
• Loose or improperly
connected wiring.
• Inspect masonry
• Blockage in flue or
chimney.
36
Corrective
Action
• Turn power OFF
prior to repair.
power to furnace
integrated control
module.
• Replace integrated
control module
module fuse (3A).
fuse with 3A
Replace if necessary.
automotive fuse.
• Turn power OFF
shorts in 115 and 24 volt
prior to repair.
circuits. Repair as
necessary.
• Read precautions
in "Electrostatic
control module.
Discharge" section
of manual.
• Locate and correct
• Turn power OFF
gas interruption.
prior to repair.
• Replace or realign
• Igniter is fragile,
igniter.
handle with care.
• Check flame sense
signal. Sand sensor
• Clean flame sensor
with steel wool.
if coated and/or
oxidized.
• See "Combustion
• Check flue piping for
and Ventilation Air
blockage, proper
Requirements" and
length, elbows, and
"Category I Venting
termination.
(Vertical Venting)"
section for details.
• Verify proper
induced draft blower
• See Product Data
performance.
Bulletin for
• Check circulator
allowable rise
blower speed and
range and proper
performance.
circulator speed.
Correct speed or
replace blower if
necessary.
• Turn power OFF
• Replace induced
prior to repair.
draft blower
pressure switch.
• Replace pressure
switch with proper
• Repair short.
replacement part.
• Turn power OFF
hose. Repair, if neces-
prior to repair.
sary,
• See "Combustion
and Ventilation Air
Requirements" and
proper length, elbows,
"Category I Venting
and termination.
(Vertical Venting)"
section for details.
setpoint or contact
• Replace pressure
motion.
switch with proper
replacement part.
connection.
• Replace masonry
vent kit limit switch
chimney and flue; remove
with correct
replacement part.
blockage.
Cautions
& Notes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gds8Ameh8Ghs8Adsh8Adss8Mh8 ... Show all