Installation - Vissani QR023 Use And Care Manual

Under cabinet range hood
Table of Contents

Advertisement

Installation

1
Removing the electrical
knock-out hole
WARNING: Always wear safety goggles and gloves
during installation.
□ Choose the appropriate electrical knock-out hole to remove
for your installation type. Use the top hole (1) for a top
venting installation and the back hole (2) for a back venting
installation.
□ Use a hammer and a flathead screwdriver to gently punch
out the electrical knock-out hole.
1
2
A
3
Testing the electrical connection
DANGER: Turn off the power circuit breaker or the
power switch on the junction box before installing this
unit. Touching circuitry inside the range hood while it is
energized will result in death or serious injury.
DANGER: All electrical wiring must be properly installed,
insulated, and grounded. Improper insulation and grounding
will result in deadly electrical shock.
NOTICE: Temporarily wire the range hood to test it
for proper operation. If the range hood does not operate
correctly, do not proceed with the installation.
□ Use the power supply cable to connect the range hood (A)
directly to the junction box or circuit breaker box. Use a
flexible, armoured, or nonmetallic sheathed copper cable
only. Never use an extension cord or adapter plug.
□ Connect a UL-listed or CSA-approved conduit connector to
each end of the power supply cable (at the range hood and
at the junction box).
□ Connect the three colored wires (3) from the range
hood (A) to the corresponding wires (4) from the electrical
2
Removing the venting hole
□ Choose the venting hole to remove for your installation
type. Use the top hole (3) for a top venting installation and
the back hole (4) for a back venting installation.
□ Using a flathead screwdriver or needle nose pliers, remove
the venting hole. Be very careful not to leave any broken
pieces inside the range hood (A).
A
source : black to black (live), white to white (neutral), and
green/yellow to green/yellow (ground). Use either the top
hole (1) or the back hole (2) of the range hood depending
on your installation type. Wire sizes must conform to the
requirements of the National Electrical Code ANSI/NFPA 70 or
the CSA Standards C22.1-94, Canadian Electrical Code Part 1
and C22.2 No. 0-M91, and all local codes and ordinances.
□ Turn the power on, and ensure that all lights and fans are
operating correctly.
□ Once you have tested the electrical connection, disconnect
the power supply cable and wires from the electrical
source before proceeding with the rest of the installation.
4
3
9
Please contact 1-800-514-6729 for further assistance.
3
4
A
1
2
H
O
M
D E
P E
T O
C .
OM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents