Baffle Nets; Troubleshooting - Vissani QR023 Use And Care Manual

Under cabinet range hood
Table of Contents

Advertisement

Care and Cleaning (continued)
BAFFLE NETS
The baffle nets fitted by the factory are intended to filter out residue and grease from cooking. You do not need to replace them on a regular
basis, but you should keep them clean.
Do
□ Clean the baffle nets once a month using
non-abrasive detergents, either by hand or in the
dishwasher. When using a dishwasher, set the
dishwasher to a low temperature and a short cycle
setting. The baffle nets may become discoloured
in a dishwasher, but this does not affect their
performance.
□ Dry the baffle nets before re-installing them in the
range hood.

Troubleshooting

DANGER: Turn off the power circuit breaker or the power
switch on the junction box before performing maintenance.
Touching circuitry inside the range hood while it is
energized will result in death or serious injury.
Problem
The range hood will not operate.
The range hood vibrates when the fan is operating.
The fans seem weak.
Do Not
□ Do not allow oil to accumulate over more than 80%
of the filter surface. Oil accumulations may drop oil
onto the range.
Solution
□ Check that the power supply cable and all electrical wiring are
properly connected.
□ Check that the power is turned on at the junction box or circuit
breaker.
□ Check that the wiring between the switch board and the control
board are connected properly.
□ Check that the range hood has been secured properly to the
wall or cabinet. Tighten it into position, if necessary.
□ Check that the motor is secured in place. If not, then tighten the
motor in place.
□ Check that the fan is not damaged. If so, replace the fan.
□ Check that the duct size used is at least 152 mm (6 in.). The
range hood will not function efficiently with insufficient duct
size.
□ Check that the duct is not clogged with debris and the tight
mesh on the wall cap, if applicable, isn't restricting air flow.
□ Check that the damper unit is opening properly, if applicable
□ Check that no birds or animals have nested in the duct.
15