Contact your local building or fi re officials regarding permits and any WARMLAND PELLET STOVE information on installation and inspection requirements in your area. TESTED and LISTED to ASTM 1509-04,...
Check all gaskets on the Door, Ash Pan and Hopper Listing information lid and replace when necessary. The Warmland PS45 Classic stove was safety tested by Intertek Testing Services NA Ltd. and is listed to the following standards: CAUTION:...
Young children should be carefully supervised minimum ash. Once you fi nd a pellet brand that burns well, when they are in the same room as the Warmland PS45 Pellet continue using this brand. High ash fuel increases the frequency stove.
FIG. #1 Pellet fuel is made from sawdust and scrap wood from many different species of wood. Pellets are either 1/4” or 5/16” in diameter and vary in length. The Warmland PS45 Classic stove 23 7/8" will burn either diameter pellets.
Installation CAUTION: DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCT WORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS. Before You Begin Please read and carefully follow all of the installation and Hearth Protection operating instructions found in this manual. Please pay special attention to the safety instructions provided in this manual.
Clearances to Combustibles 3” Clearances: Front 48” (1.2m) Side 6" (155mm) Back 3” (76mm) 3” The center of the fl ue is 16-1/2” above the surface upon which the stove rests. Fig# 3a Corner Install IMPORTANT INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
Page 8
Vent Terminal Minimum Clearances Fig. #4 FIXED OPEN- CLOSED ABLE FIXED CLOSED OPEN- ABLE AREA WHERE TERMINAL GAS METER AIR SUPPLY INLET VENT TERMINAL IS NOT PERMITTED ALL CLEARANCES ARE MINIMUMS A= *12 inches (30 cm) Clearances above non combustible grade *24 inches (60 cm) Clearances above grass, top of plants, wood, combustible veranda, porch, deck, or balcony B= *48 inches (120 cm)
Vent Termination Requirement 3 .Vent surfaces can become hot enough to cause burns if touched. Non-combustible shielding or guards may be required. 1. Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, attic, crawlspace, narrow 4.
Venting Installing into a Wood Stove Pipe The Warmland PS45 Classic stove can be vented into existing This heater is approved for venting with any 3" or 4" Type PL 6” inside diameter approved wood stove pipe using approved and Type L pellet vent pipe listed to UL 641 and ULC S609.
Page 11
Fig #6 Chimney Recommended Recommended Chimney Connector The chimney may incorporate an offset. To do this safely, all sections of listed connector, offset elbows and chimney Caution: This confi guration May section must be screwed to- Not be allowed in some gether by at least three sheet areas.
Thermostat installation Operation The Warmland PS45 Classic stove can be operated manually Filling the Hopper or by a thermostat. The stove comes from the factory in the The hopper can be accessed by lifting the hopper lid in the manual mode. To operate in the two "Thermostat" modes a top.
Operating Sounds free of fi ngerprints before lighting stove. Fingerprints will leave As the Warmland PS45 Classic stove is burning, a number of permanent blemishes if left on plated surface when hot. The door normal operational sounds may be heard. When the blowers should be gently cleaned with a soft cloth and glass cleaner.
Routine Checks and Maintenance Inspection /cleaning weekly monthly yearly Ash Pan - Leg Model or Every 15 bags of fuel burned Burn-Pot or Every 5 bags of fuel burned Burn-Pot Liner or more frequently depending on fuel quality Blower - Convection or more frequently if pets present Blower - Exhaust or more frequently depending on fuel quality...
CAUTION: Disposal of Ashes - Ashes should be placed in Fig. #11 a metal container with a tight fi tting lid. The closed container should be placed on a non-combustible fl oor or the ground – well away from all combustible materials, pending fi nal disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled.
Cabinet Side Removal Fig. #16 Remove the two screws holding the back of the Cabinet Side to the chassis. Lift up slightly to disengage the screws at the front and pull off. Installation is the reverse. Firebox liner Fig. #14 screw Fig.
Cleaning the Combustion Blower: Door Removal To clean the combustion blower, unplug the stove, remove the left cabinet side. Loosen but do not remove the six screws CAUTION: Do not open the Firebox door when the stove is (Fig.#18) with an 1/4” nut driver or socket. Rotate the motor hot or operating.
Fire-Pot Liner. Draft Damper CLOSED The Warmland PS45 Classic stove has a draft damper located at the left side of the stove directly in front of the combustion OPEN blower.