Download Print this page

Acom SI-1 Owner's Manual page 7

Bench scale

Advertisement

Simple Weighing
1. Make sure that the scale is at ZERO and STABLE
2. Place a load on the platter
3. After the STABLE indicator turns on you may read the weight
4. Remove the load
Entering Tares
1. Make sure that the scale is at ZERO and STABLE
2. Place the container to be tared on the platter
3. After the STABLE indicator turns on press the TARE key
4. The display should be at zero and the NET, STABLE, and ZERO
lamps should all be on
Removing Tares
1. Make sure that the scale is at ZERO, STABLE, and NET
2. Remove the tared container from the platter
3. The display should be at a negative weight and the NET,
STABLE, and ZERO lamps should all be on
4. Press the TARE key
5. The display should now show zeros and be at ZERO and
STABLE
Simple Weighing Using Tares
1. Make sure that the scale is at ZERO and STABLE
2. Follow directions for entering a tare
3. Place a load on the platter
4. After the STABLE indicator turns on you may read the weight
5. Remove the load
6. You may continue to use the same tare by returning to step 3 in
this procedure, OR continue to step 7
7. Follow steps for Removing Tares
Parts Counting (This feature is NOT legal for trade.)
1. Press the MODE key until you reach Counting mode
2. Make sure that the scale is at ZERO, STABLE and PCS
3. Press the SET key
4. The display will read SEt 10
5. Place sample of 10 pieces on the platter and press the SET key
6. If the sample is not within the Minimum Piece Weight and
Minimum Sample Weight for the scale's specific capacity, then the
scale will loop back to step 5 but this time asking for a sample of
20 pcs; if it fails again then 50 pcs; and finally 100 pcs.
(continued)