Fusing Unit Error - Oki OKIPAGE 12i Service Handbook

Digital led printer
Hide thumbs Also See for OKIPAGE 12i:
Table of Contents

Advertisement

4
Fusing unit error (ERROR 71) (ERROR 72) (ERROR 73)
• Turn the power off, then back on again.
• Yes
Is the thermistor open or shorted? Measure the resistance between thermistor contacts
(heater contacts 120V/3Ω or 240V/10Ω, and thermistor contacts 200KΩ at room
temperature) (see Figure 6-2 or Section 7.3).
• Yes Replace the fusing unit.
• No
Do the thermistor contacts touch the contact assembly properly when the fusing unit
is mounted in the printer?
• No Adjust the contacts of the contact assembly.
• Yes
Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)?
• Yes
• No
Is the AC voltage being supplied to the contacts for the heater of the contact assembly?
(see Figure 6-2)
• No
• Yes
Check the heat contacts of the fusing unit and the contact assembly for poor contact
(see Figure 6-4 contact
Check the thermistor contacts or replace the main control board or the fusing unit.
Replace the main control board or the power supply/sensor board.
).
G
Heater contacts
Themistor contacts
Figure 6-2
6 - 21

Advertisement

Table of Contents
loading

Table of Contents