Kenwood TK-860G Service Manual page 53

Uhf fm transceiver
Hide thumbs Also See for TK-860G:
Table of Contents

Advertisement

Item
Condition
8. MIC
1) Set test mode
seisitivity
CH : CH1 - Sig1
check
AG : 1kHz/5mV
PTT : ON
9. QT deviation 1) Set test mode
• Wide/
Select "FQT" in tuning mode. AG
Narrow
"_.FQT"
Deviation meter filter
LPF : 3kHz, HPF : OFF
PTT : ON
Adjust [ *** ]
2) "_.F.Q.T"
PTT : ON
Adjust [ *** ]
3) "_.F.Q.T._."
PTT : ON
Adjust [ *** ]
• Semi wide 4) "_FQT *** ."
PTT : ON
Adjust [ *** ]
10. DQT
1) Set test mode
deviation
Select "FDQT" in tuning mode.
• Wide/
"F.DQT"
Narrow
Deviation meter filter
LPF : 3kHz, HPF : OFF
PTT : ON
Adjust [ *** ]
2) "F.D.Q.T"
PTT : ON
Adjust [ *** ]
3) "F.D.Q.T._."
PTT : ON
Adjust [ *** ]
• Semi wide 4) "FDQT *** ."
PTT : ON
Adjust [ *** ]
11. DTMF
1) Set test mode
deviation
Select "DTMF" in tuning mode.
• Wide/
Deviation meter filter
Narrow
LPF : 15kHz, HPF : OFF
PTT : ON
Adjust [ *** ]
• Semi wide 2) "DTMF *** ."
PTT : ON
Adjust [ *** ]
12. TONE
1) Set test mode
deviation
Select "TONE" in tuning mode.
• Wide/
Deviation meter filter
Narrow
LPF : 15kHz, HPF : OFF
PTT : ON
Adjust [ *** ]
• Semi wide 2) "TONE *** ."
PTT : ON
Adjust [ *** ]
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
Deviation
panel
meter
Oscilloscope
AF VTVM Front
MIC
Front
panel
panel
Front
panel
Front
panel
Front
panel
TK-860G/
(
N
Adjustment
Parts
Method
Check
CH /
0.75kHz (Wide)
0.35kHz (Narrow)
0.6kHz
CH /
0.75kHz (Wide)
0.35kHz (Narrow)
0.6kHz
CH /
3.0kHz (Wide)
1.5kHz (Narrow)
2.4kHz
CH /
3.0kHz (Wide)
1.5kHz (Narrow)
2.4kHz
)
/862G/
(
N
)
Specifications/Remarks
± 2.4kHz~± 3.4kHz (Wide)
± 1.2kHz~± 1.7kHz (Narrow)
± 50Hz
± 50Hz
± 0.1kHz (Wide)
± 0.05kHz (Narrow)
± 0.1kHz
± 0.1kHz (Wide)
± 0.05kHz (Narrow)
± 0.05kHz