CHAPTER 5: RMS REMOTE MONITORING SYSTEM

The Acheron Designer is optionally available with the RMS
remote monitoring system module, allowing it to be con-
nected to an RMS network. RMS allows real-time monitor-
ing of multiple Meyer Sound self-powered loudspeakers
from a Windows-based computer. The RMS host computer
communicates with Meyer Sound loudspeakers (equipped
with RMS modules) via a simple twisted pair network, or an
Ethernet network using an FT-10 to Ethernet adapter.
NOTE:
For the latest RMS system require-
ments, visit www.meyersound.com.
NOTE:
The RMS software allows you to dis-
able Mute and Solo functions to eliminate any
possibility of accidentally muting loudspeakers. Mute
and solo capability can also be disabled by removing
the Mute Jumper from RMS modules. For more infor-
mation, refer to the RMS User Guide.
NOTE:
RMS does not control AC power.

RMS SOFTWARE

The optional RMS software provides extensive system sta-
tus and performance data for each loudspeaker, including
amplifier voltage, limiting activity, power output, driver sta-
tus, as well as mute and solo capability. Loudspeakers are
added to the RMS network and assigned a node name dur-
ing a one-time commissioning procedure where the loud-
speaker is identified by either entering its unique Neuron ID,
or by pressing its Identify button.
RMS Add Loudspeaker Dialog Box
Once loudspeakers are identified on the RMS network, they
appear in the RMS software as icons and views; they are
also automatically added to the RMS database on the host
computer.