High Definition
Reinforcement
Operating Instructions
Loudspeakers
The Meyer Sound
UPL-1 and UPL-2 are
self-contained, high-
definition, powered
loudspeakers suitable
for a wide variety of
high quality sound
reinforcement appli-
cations. The UPL-1
and UPL-2 incorpo-
rate line-level control
electronics mounted
within a rear panel
chassis, including:
• dual power
amplifiers for
biamplification
• an active balanced
input circuit with
switchable sensi-
tivity (+4 dBu or
-10 dBV)
• an active crossover
utilizing optimized
pole-zero filter
combinations to
achieve acoustical
transparency and
linear phase
The UPL-1 and UPL-2 are two-way systems
• independent pro-
comprising a 10-inch cone low-frequency
tection circuits for
driver and 1-inch high-frequency driver housed
each loudspeaker
driver
in a vented cabinet. Both drivers are of a pro-
prietary design, and are individually selected
for maximum linearity. The high-frequency
horn driver employs a titanium dome and silk
suspension in a patented, low distortion design
(US patent number 4,152,552). It is coupled to
a 90
and to a 60
Meyer Sound Laboratories, Inc.
2832 San Pablo Avenue
Berkeley, CA 94702
°
°
by 40
modified radial horn in the UPL-1,
°
aspherical waveguide in the UPL-2.
Aligned to closely approximate true point
source radiators within their coverage area,
the UPL-1 and UPL-2 feature tightly controlled
time delay response with minimal deviation
from linear phase across the full frequency
range of their operation. Each unit is individu-
ally factory-calibrated to ensure a free-field
frequency response that is flat within
from 50 Hz to 18 kHz. The UPL-1 and UPL-2
each deliver 124 dB peak SPL (1 meter) with
>100 dB dynamic range.
±
2 dB

Advertisement

loading

Summary of Contents for Meyer Sound UPL-2

  • Page 1 ± suspension in a patented, low distortion design frequency response that is flat within 2 dB (US patent number 4,152,552). It is coupled to from 50 Hz to 18 kHz. The UPL-1 and UPL-2 ° ° a 90 by 40...
  • Page 2 -10 dBV • +4 dBu position: setting. Driving the UPL-1 or UPL-2 from a +4 dBu 1.23 VRMS = 114 dB SPL source with the switch set to -10 dBV will result in • -10 dBV position: increased noise.
  • Page 3 Reinforcement Operating Instructions Loudspeakers Installation The UPL-1 and UPL-2 are are aligned for flat fre- Note. The UPL-1 and UPL-2 are not weather- quency response in free field (no adjacent bound- resistant, and should not be installed outdoors ary surfaces). Placing either unit next to a wall or where they may be exposed to the elements.
  • Page 4 UPL-1 & UPL-2 High Definition Reinforcement Operating Instructions Loudspeakers Acoustical Specifications ±2 dB from 50 Hz to 18 kHz Frequency Response -3 dB at 32 Hz and 20 kHz Phase Response +60°, -0° from 120 Hz to 18 kHz Maximum SPL...

This manual is also suitable for:

Upl-1