6
Secure the power supply cord and connecting cable onto the control board with the holder.
7
Attach the control board cover back to the original position with the screw.
8
For wire stripping and connection requirement, refer to instruction 11.2.4 of the indoor unit.
This equipment must be properly earthed.
Note: Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
Always ensure all above connections compliant with national wire rules.
11.3.5

Piping Insulation

1
Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation
Diagram. Please wrap the insulated piping end to prevent water from going inside the piping.
2
If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by
using POLY-E FOAM with thickness 6 mm or above.
WARNING