Panasonic CS-E7PKR Service Manual page 93

Hide thumbs Also See for CS-E7PKR:
Table of Contents

Advertisement

13.13.1.7 Setting Position Judgment
According to installation position when there is only one activity area detected, the horizontal airflow direction
louver position is fixed according to chart below:
Target area
A
B
C
Louver position refer to horizontal airflow direction control.
When 2 activity areas have been detected, according to Human Activity Level, the timing of horizontal airflow
direction louver steps at the targeted activity areas is judged.
Operation mode
Cooling
When 3 activity areas have been detected, according to Human Activity Level the timing of horizontal airflow
louver steps at the targeted activity areas is judged.
Operation mode
Cooling
When 3 activity areas have same activity level, the horizontal airflow direction louver will swing left and right.
13.13.2 Setting Temperature and Fan Speed Shift
Cooling Dual Sensor
Horizontal airflow direction louver position
Left installation
Center installation
3
1
5
Activity level difference
1 level
2 levels
Activity level
Hi
Me
Lo
Right installation
2
1
5
Louver stop time
Higher Activity level ≈ 60 seconds
Lower Activity level ≈ 30 seconds
Higher Activity level ≈ 60 seconds
Lower Activity level ≈ 8 seconds
Louver stop time
≈ 45 seconds
≈ 30 seconds
≈ 20 seconds
93
2
1
4

Hide quick links:

Advertisement

Table of Contents
loading