Before You Call
Solutions
to Common
Problems
Before you carl for service, review this list. It may save you time and expense. The list includes common occurrences that
are not the result of defective workmanship or materials in this appliance.
OCCURRENCE
Range is not level.
Cannot
move appliance
easily. Appliance
must be accessible
for service.
Surface
burners
do not light.
Surface burner flame burns halfwayaround.
Surface
burner
flame is orange.
Oven does not operate.
Entire appliance
does not operate.
POSSIBLE
CAUSE/SOLUTION
Poor installation. Place oven rack in center of oven. Place a level on the oven rack. Adjust
leveling legs at base of range until the rack is level. When range is level, cooktop may
appear out of alignment if countertop
is not level.
Weak, unstable floor. Be sure floor is level and can adequately support range. Contact
a carpenter to correct sagging or sloping floor.
Kitchen cabinet misalignment
may make range appear to be unlevel. Be sure cabinets
are square and have sufficient room for range clearance.
Cabinets
not square or are built in too tight. Contact a cabinet maker to correct the
problem.
Contact builder or installer to make appliance accessible.
Carpeting
interferes with range. Provide sufficient
space so range can be lifted over
carpet.
Gas line is hard-plumbed.
Have a flexible C.S.A. International
approved metal appliance
connector
installed.
Surface Control knob has not been completely
turned to LITE. Push in and turn the
Surface Control knob to LITE until burner ignites and then turn control knob to desired
flame size.
Burner ports are clogged. With the burner off, use a small-gauge
wire or needle to clean
ports. See "Surface
Burners" in the General
Care & Cleaning
table for additional
cleaning
instructions.
Range power cord is disconnected
from outlet (electric ignition models only). Be sure
cord is securely plugged into the outlet.
Electrical power outage (electric ignition models only). Burners can be lit manually. See
Setting
Surface Controls.
Burner ports are clogged. With the burner off, clean ports by using a small-gauge
wire
or needle.
Moisture is present after cleaning. Lightly fan the flame and allow burner to operate until
flame is full. Dry the burners thoroughly
following
instructions
in the General
Care &
Cleaning
section.
Dust particles in main line. Allow the burner to operate a few minutes until flame turns
blue.
In coastal areas, a slightly orange flame is unavoidable
due to salt air.
Be sure the oven controls are set correctly for the desired function. See Setting
Oven
Controls
or Entire Appliance Does Not Operate (see below).
Be sure regulator gas valve is "ON". See installation instructions.
Check house circuit breakers.The time of day must be set in order to operate the oven.
Oven light does not work.
Make sure electrical cord/plug is plugged tightly into outlet (electric ignition models only).
Service wiring not complete. Call 1=800=4=MY=HOME® for assistance (See back cover).
Electrical power outage (electric ignition models only). Check house lights to be sure.
Call your local electric company for service. Surface burners can be lit manually. See
Setting
Surface Controls.
Be sure gas supply is turned on.
Burned-out or loose bulb. See Changing
the Oven Light (some models) to replace or
tighten the bulb.